background image

 

10.

 

  User operation 

      10.1 User to release the door 

Card user:  

.

Read card

.

 

Fingerprint user:  

.

Input fingerprint

.

 

      10.2 Remove alarm 

When the device alarm is activated (from the built in buzzer or the external alarm), to remove it: 

.

Read valid user card or fingerprint

.  

or  

.

Manager card or fingerprint

.  

or  

.

Master code

11.

 

  Advanced applications 

     11.1  FP1-PROX works as a slave reader, connecting to a controller 

FP1-PROX supports Wiegand output. It can be connected to a controller which supports Wiegand 26 input 
as its slave reader, connections as shown in the following diagram: 

 

 

 

 

 

 

If the controller has a PC connection, the users ID can be shown in the software. 

a)

 

Card user, its ID is the same as the card number. 

b)

 

Fingerprint user, its ID is the combination of device ID and fingerprint ID. The device ID is set as below: 

 

.

*

.  .

Master code

.  .

#

.  .

3

.  .

Device ID

.  .

#

.

 

Device ID can be any digit between 0 & 255 
For example, if device ID was set to 255 and fingerprint ID is 3, then its ID to the controller is 255 00003. 

    11.2  FP1-PROX works as controller, connecting slave reader 

FP1-PROX supports Wiegand input, any card reader which supports Wiegand 26 interface can connect to it 
as a slave reader, regardless of what type of cards it reads (EM, MIFARE, etc.) The connections are shown 
in the below diagram. When adding cards, it is required to do it at the slave reader, not the controller 
(except EM card reader, which can be added on both the reader and controller). 
 

 

 

 

 

 

 

 

 

Summary of Contents for FP1-PROX

Page 1: ...inc Quantek 59 Sheffield Road Dronfield S18 2GF 44 0 1246 417113 sales cproxltd com www quantek co uk Fingerprint Access Control FP1 PROX User Manual Please read the manual carefully before installing...

Page 2: ...ntification technology making it safe and reliable which means it is an ideal choice for situations demanding high security Its programming is done by infrared remote control master fingerprint or man...

Page 3: ...cm Resolution 450 DPI Fingerprint input time 1s Identification time 1s FAR 0 0000256 FRR 0 0198 Structure Zinc alloy Dimensions 115 x 70 x 35 mm Weight 500g 5 Installation Remove the back cover using...

Page 4: ...Alarm Alarm negative Yellow OPEN Exit button Brown D_IN Door contact Red 12V 12V DC regulated power input Black GND 12V DC regulated power input Blue GND GND for exit button and door contact Purple L...

Page 5: ...short rings Unlock the Door Green Long ring Alarm Quick flash in red Bright Alarm 9 Manager operation There are 3 ways to add and delete users 1 By manager card 2 By remote control 3 By manager finge...

Page 6: ...1 ID number Input user fingerprint twice Fingerprint user ID number can be any digit between 3 1000 One fingerprint per ID number To add fingerprint users continuously 1 3 Input 1st user fingerprint t...

Page 7: ...fingerprint twice Manager add fingerprint Card Manager add fingerprint User card Manager add fingerprint 9 3 4 Add users continuously Fingerprint Manager add fingerprint Input 1st user fingerprint tw...

Page 8: ...ed after one minute the internal buzzer will sound automatically the alarm will turn off after one minute b If the door is forced open or the door was not opened within two minutes of the lock being r...

Page 9: ...ers ID can be shown in the software a Card user its ID is the same as the card number b Fingerprint user its ID is the combination of device ID and fingerprint ID The device ID is set as below Master...

Page 10: ...If the master codes were set different the user enrolled in the outdoor unit can t access from the inside 11 4 Two devices interconnected interlocked Two doors The connection as shown below is for tw...

Page 11: ...11 12 Issue record Site Door location User ID number Card fob number User name Issue date...

Reviews: