Digital clamp meter

C-LOGIC 8900

Code: 301000060

INSTRUCTIONS MANUAL

ENGLISH 

EN

GENERAL DESCRIPTION

The 3-phase clamp-type digital power meter is a handheld intelligent harmonic power tester, 

with both functions of digital current testing and power testing. The tester is comprised 

of three channels including voltage, current, and power as well as a micro single chip 

system, and it is equipped with a powerful software for measurement and data processing 

functions; it can measure, calculate, and display voltage, current, active power, power factor, 

apparent power, passive power, frequency, harmonic parameters, with stable performance 

and operation convenience. The meter is especially suitable for the measurement and 

examination of on-site power equipment and power-supplying circuits; with hand-held clamp 

structure, small volume, and lightweight, it can be easily carried by the user, which makes 

it easy and fast for doing measurement. The meter is your ideal choice for measurement of 

single-phase/ three-phase power. 

SAFETY INSTRUCTIONS

The three-phase clamp-type digital power meter is designed and manufactured in 

accordance with international standard, IEC61010-1, and international safety specification, 

IEC1010-2-032, and the meter strictly follows the safety standard of double-insulation AC 

600 V CAT III.

SAFETY REQUIREMENTS

Please carefully read the instruction manual before using the tester, and pay special 

attention to “Warning” content. Please follow instructions under “Warning”.

• 

Please be very careful when test voltage is higher than AC 30 V, and do keep in mind that 

your finger shall not exceed the hand-shielding part of the test probe.

•  Do not measure voltage which is higher than the allowed input limit.

•  Before use, please check the meter and test probe; do not carry out testing in case the test 

probe is naked, tester housing is damaged, or there is no LCD display, etc..

• 

It meets requirements of safety standards only when the meter is used together with the 

supplied test probes. In case the test probe is damaged and needs replacement, it is required 

to replace it with a test probe of the same model and identical electrical specifications.

•  Please never carry out any voltage measurement whenever the test probe is inserted in 

any current outlet.

•  Please do not expose the meter to strong light, high temperature, or dampness.

 Warning

Before use, please carefully read this instruction manual. Especially safety contents!

REPLACING TEST LEADS

Replace test leads if leads become damaged or worn. 

 Warning

Use meet EN 61010-031 standard, rated CAT III 600V, or better test leads.

REPLACING THE BATTERIES

 Warning

To avoid electric shock, make sure that the test leads have been clearly move away from 

the circuit under measurement before opening the battery cover of the meter.

 Warning

Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or 

rechargeable (ni-cad, ni-mh, etc) batteries.

• 

If the sign “

” appears, it means that the batteries should be replaced.

• 

Loosen the fixing screw of the battery cover and remove it.

•  Replace the exhausted batteries with new ones.

• 

Put the battery cover back and fix it again to its origin form.

Note:

 

Do not reverse the polarity of the batteries.

ACCESSORIES

• 

Short Instruction manual 

 

1

• 

1.5V AA Baterry 

 

 

4

•  Test 

probe   1

•  Test 

clip 

   3

• 

Interface cable 

 

 

1

•  PC Software CD 

 

 

1

•  Package 

box 

  1