TECHNICAL PARAMETERS:
Operating voltage
9V CC (CR2450 3V x 3)
Current
Corriente de reposo: < 10uA
Corriente de alarma: < 20mA
Alarm decibels
≥ 85dB/3m
LED indicator
LED (rojo)
Low voltage alarm
≤ 7,35V
Operating temperature
-10º ~ +40º
Ambient humidity
≤95% HR (sin condensación)
Regulations
EN 14604:2005/AC:2008
Intended for Fire Safety and installed in
buildings
Essential characteristic 1: Pass
Essential characteristic 2: Pass
Essential characteristic 3: Pass
Essential characteristic 4: Pass
Essential characteristic 5: Pass
Essential characteristic 6: Pass
Essential characteristic 7: Pass
Essential characteristic 8: Pass
APPEARANCE AND DIMENSIONS
(mm) (
see Figure
1)
TEST
(
see Figures 2, 3 and 4
):
Note: If the battery is not installed correctly, the detector will not function and may be
damaged. The red LED will flash once every 43 seconds to indicate that the detector is
working properly.
1.
Turn the installation panel counterclockwise to remove it (See Figure 2).
2. Remove the insulation material and make sure the battery is connected correctly (See
Figure 3).
3. Insert the 3 tabs of the installation panel into the 3 slots of the detector and turn the
smoke detector clockwise to secure it (See Figure 4).
4. Press the test button, the red LED will flash quickly and the detector will beep, which
means the detector is working properly.
INSTALLATION (see Figure 5)
:
1.
Choose a suitable place to install the smoke alarm (ceiling)
2.
Use a screw to fix the installation plate to the ceiling
3. Turn the smoke detector clockwise to secure it to the installation plate
Avoid using the product in damp, dusty or smoky environments.
LOW VOLTAGE ALARM
When the battery reaches a low power level, the detector will sound to indicate that the
battery needs to be replaced.
ATTENTION
Test the smoke alarm weekly. If the product does not work properly, please check the
battery. If the battery is OK, do not open the product yourself, contact a professional.
QUALITY AND GUARANTEE
This product has a two-year manufacturer's warranty.
Damage caused by the user or by improper use of the product is not covered by the
warranty.
Mini smoke detector
C-LOGIC 720-SD
SKU: CLOGIC720SDCBINT
INSTRUCTION MANUAL
ENGLISH
E
NG
ASPECT AND DIMENSIONS
(mm)
(Figure 1)
Figur
e
1
TEST (Figures 2, 3 and 4)
Figur
e
2
Figur
e
3
Figur
e
4
INSTALLATION
(Figur
e
5)
Y
ou can
download the complete manual at the URL
https://clogic-intl.com/clogic-720-sd
FULL MANUAL DOWNLOAD
MANUFACTURER:
MGL International
APAC:
MGL GLOBAL SOLUTIONS LTD
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA:
MGL EUMAN S.L.
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
AMERICAS:
MGL AMERICA, LLC.
US East Coast:
2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast:
760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com