18
ELECTRICAL INSTALLATION
1.
Mount the “pre-wired” electronic control panel in a suitable location. Have a qualified
electrician run power to the panel and connect it into the TB1 Terminal block
2.
Run 1/2” electrical conduit to the concrete pedestal location as discussed earlier.
3.
Connect the wiring from the TB3 terminal block, located in the “pre-wired” electronic
control panel, to the gate operator. See Figure 5 for wiring diagram.
4.
Remove the lockout device from the circuit breakers at the service panel and label them
“Gate operating equipment.” Switch breakers to the “On” position to energize the
system.
5.
Operate the gate and make necessary adjustments to ensure safety, correct speed, and
smooth operation. Refer to the sections below for instructions on how to adjust the
operator.
6.
Determine the amount of force it takes to stop the movement of the gate, and adjust the
relief valve settings as required. The maximum allowable force to meet UL325 4th
edition is forty (40) pounds.
7.
Test all safety reversing and access control devices for correct response.
8.
Install the sheet metal cover over the operator frame and fasten with the bolts provided.
9.
Run a final test of the entire system.
10.
Hang placards and any audio warning devices in highly visible and audible areas.
11.
Instruct the end user and all parties having access to the vehicular gate operating
equipment on the operation of the gate controller, and on the operation procedures in the
event of a power failure.