![Byan Systems HYD 1000 Installation And Technical Manual Download Page 13](http://html.mh-extra.com/html/byan-systems/hyd-1000/hyd-1000_installation-and-technical-manual_2836904013.webp)
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
10
PRE-INSTALLATION
Before Installation:
1.
Automatic slide gates require a number of safe guards against entrapment and pinch points.
Verify that protective devices have been installed to prevent bodily injury and/or death. If
none are present, advise the customer before continuing the installation.
2.
Move the existing slide gate forward and backward by hand, noting any areas that need
maintenance, and also note any elevation changes in the road surface grade that may exist. If
the gate does not travel smoothly, perform the necessary maintenance before beginning the
installation.
We recommend a V-wheel on a v-track or pipe track, or some other means
of ensuring the gate moves forwards and back on a straight line and with smooth
operation.
Special precautions must be taken to ensure that smooth operation results when
using cantilevered gates.
3.
Locate the commercial power source that will be used to supply power to the gate control
panel. Identify the breakers and visually confirm that they are rated for the application and in
the “Off” position. Install an approved lockout device on the breakers to prevent them from
being accidentally energized during the installation of the operator.
4.
If the commercial power wiring has already been installed, inspect the installation for
compliance to pertinent electrical codes prior to making any connections.
5.
If any discrepancies are found that compromise life-safety and or entrapment, do not install
the automatic gate equipment until the discrepancies are corrected.