Adjustment Procedure:
1. To set the amount of delay between the first leaf opening and the second leaf opening,
turn the open delay time (left timer) with a small screwdriver. To increase the open
delay, turn the timer counterclockwise. To decrease the open delay, turn the delay
timer clockwise.
2. To set the amount of delay between the second leaf closing and the first leaf closing,
turn the close delay timer (right timer) with a small screwdriver. To increase the
close delay, turn the timer counterclockwise. To decrease the close delay, turn the
timer clockwise.