background image

BYAN SYSTEMS, INC. 

Automated Gate and Access Control Products 

 
 

413 Linden • Lusk, WY 82225 • (800) 223-2926 

 

4

 

Accessory Terminal Table 

 

Terminal 
Numbers 

Terminal Name 

Possible Uses 

1 - 2 

Alarm Output 

These terminals allow the connection of a 
device to alert the user that people safe 
has been activated. 

3 - 4 

24V AC 1A Output 

Power for accessories such as radio 
receivers, loop detectors, or anything  
requiring 24V AC 1A may be connected  
here. 

5 – 6 

12V DC 1A Pulsed 
Electric Lock 
Output 

Magnetic or other types of lock release signals may be 
connected here. 

7 – 9 

People Safe Alarm Reset 
Input 

A button or other N/O contact may be connected here to 
reset the people safe alarm output relay. 

People Safe Input 

N/C people safe devices such as sensing edges are 
connected here. 

Safety Common Input 

Common wires for people and car safety devices are 
connected here. 

10 

Car Safe Input 

N/C car safe devices such as loop detectors and photo 
beams are connected here. 

11 

Limit Switch Common 
Input 

If limit switches are required, the common 
Wires would be connected here. 

12 

Close Limit Switch Input 

If limit switches are required, the close limit switch would 
be connected here. 

13 

Open Limit Switch Input 

If limit switches are required, the open limit switch would 
be connected here. 

14 – 15 

Stop Input 

A N/C device used to stop the operators such as a button 
may be connected here. 

16 

Control Function 
Common Input 

This is where the common of devices used to open, close, 
or reverse the gate would be connected. 

17 

Close Function Input 

Devices only used to close the gate such as in ground 
loops, buttons, or photo beams are connected here. 

18 

Open Function Input 

Devices only used to open the gate such as in ground loops, 
buttons, or radio receivers are connected here. 

19 

Reverse Function Input 

 Devices used to reverse the gates direction 
 such as in ground loops, buttons, or radio 
 receivers are connected here. 

 
 

 

 

Summary of Contents for G2M

Page 1: ...ecifications Power supply Single Phase 115V or 220V 50 60 Hz AC Motor Power Consumption Up to 550W or 3 4 hp Electric Lock Output 12V DC 1A max Accessory Power Output 24V AC 1A max Input Power Fuse 2A 250V 5mm x 20mm tubular glass Motor Power Fuses 6A 250V 5mm x 20mm tubular glass P O BOX 1384 FAX 307 334 2028 ...

Page 2: ...minal Table 3 Commercial Power Hook Up 3 Accessory Terminal Table 4 Accessory Hook Up 5 Timing Potentiometers 6 S1 DIP Switches Table S1 S1a 6 S2 DIP Switches Table S2 7 Power and Motor Run Terminal Strip Conversion Tables 8 Accessory Terminal Strip Conversion Tables 8 12 X 10 and 20 X 16 Prewire Layouts 10 24 X 20 Prewire Layout 11 Trouble Shooting Guide 12 T2M Leaf Delay Card 14 Warranty 15 ...

Page 3: ... leaf delay card comes standard with every board A traffic light card and a receiver card are available separately There are three timing potentiometers as well as nine DIP switches incorporated into the board to control different output functions Terminal Strips There are two sets of terminals on the G2M control board The first terminal strip is the power and motor run terminal block located on t...

Page 4: ... Two Close Directional Black 7 Motor Two Open Directional Red 8 Motor Two Common White Commercial Power Hook Up 1 Hook up commercial power to terminals 1 2 of the power and motor run terminal strip 2 Connect leads from the 1 operator to terminals 3 4 5 of the power and motor run terminal strip 3 Connect leads from the 2 operator to terminals 6 7 8 of the power and motor run terminal strip 4 Connec...

Page 5: ...ted here 10 Car Safe Input N C car safe devices such as loop detectors and photo beams are connected here 11 Limit Switch Common Input If limit switches are required the common Wires would be connected here 12 Close Limit Switch Input If limit switches are required the close limit switch would be connected here 13 Open Limit Switch Input If limit switches are required the open limit switch would b...

Page 6: ...er 7 Drill 1 3 8 hole in the enclosure where you would like to mount the antenna 8 Install the bulk head connector in the hole using the hardware included with the receiver Be sure to use thread locking compound in the threads when installing the connector 9 Connect the supplied coax between the receiver and the bulk head connector and attach the antenna to the outside of the connector Mag Lock Re...

Page 7: ...versing Stroke Function When turned on the operators will first close for 1 sec before opening 2 Step by step Function When turned on each movement of the operators by any reverse input will require an individual input deactivates automatic re open function 3 Automatic Closing Function When turned on the operators will close by the time set with the yellow timing potentiometer 4 Reverse Button Ino...

Page 8: ...n Description 1 Doubling Time When turned on maximum opening and closing time is extended from 30 seconds to 1 minute and maximum pause time is extended from 45 seconds to 1 minute 30 seconds 2 Repositioning the Door When turned on the operators will cycle in the last direction of operation for 2 seconds every hour G2M to Byan Prewire Terminal Conversion Tables G2M Power and Motor Terminal Strip t...

Page 9: ...Strip to Byan 30 x 24 Prewire G2M Terminal Number 24 x 20 Terminal Strip Terminal Number 1 TB1 3 115V 2 220V 2 TB1 2 115V 1 220V 3 TB4 TB5 2 4 TB4 TB5 3 5 TB4 TB5 4 6 TB4 TB5 6 7 TB4 TB5 7 8 TB4 TB5 8 G2M Accessory Terminal Strip to Byan 12 x 10 Prewire G2M Terminal Number 12 x 10 Terminal Strip Terminal Number 3 TB3 1 4 TB3 2 8 TB3 3 9 TB3 4 10 TB3 5 16 TB3 6 18 TB3 7 19 TB3 8 G2M Accessory Termi...

Page 10: ...rminal Strip Terminal Number 3 TB5 TB7 1 4 TB5 TB7 2 8 TB5 TB7 3 9 TB5 TB7 4 10 TB5 TB7 5 16 TB5 TB7 6 18 TB5 TB7 7 19 TB5 TB7 8 G2M Accessory Terminal Strip to Byan 30 x 24 Prewire G2M Terminal Number 12 x 10 Terminal Strip Terminal Number 3 TB6 TB8 1 4 TB6 TB8 2 8 TB6 TB8 3 9 TB6 TB8 4 10 TB6 TB8 5 16 TB6 TB8 6 18 TB6 TB8 7 19 TB6 TB8 8 See Prewire layouts on pg 8 9 for reference ...

Page 11: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 10 Byan Systems 12 x 10 20 x 16 Prewire Layouts ...

Page 12: ...BYAN SYSTEMS INC Automated Gate and Access Control Products 413 Linden Lusk WY 82225 800 223 2926 11 Byan Systems 24 x 20 Prewire Layout ...

Page 13: ...ston movement Capacitor bad or not hooked up bypass screw on operator backed out Check that capacitors are hooked up if one is suspect switch capacitors and see if the problem follows the capacitor make sure bypass screw is screwed in and snug Safety devices connected properly but not functioning properly Jumpers in term 8 9 10 are still in safety device is malfunctioning If car safe is used make ...

Page 14: ...en delay timer sets the delay between the opening of the first leaf and the opening of the second leaf The close delay timer set the delay between the closing of the second leaf and the closing of the first leaf There are also inputs on the card for open and close limit switches for the second leaf if limit switches are required Adjustable Timers Timer Description Minimum Delay Maximum Delay Open ...

Page 15: ...elay time left timer with a small screwdriver To increase the open delay turn the timer counterclockwise To decrease the open delay turn the delay timer clockwise 2 To set the amount of delay between the second leaf closing and the first leaf closing turn the close delay timer right timer with a small screwdriver To increase the close delay turn the timer counterclockwise To decrease the close del...

Page 16: ...re and extent of the dealer s warranty if any There are no obligations or liabilities on the part of Byan Systems Inc for consequential damages arising out of or in connection with the use or performance of these products or other indirect damages with respect to loss of property revenue r profit cost of removal original installation or reinstallation Warranty will be considered void if damage or ...

Reviews: