Water connections
Note!
All water connections of the plant shall be installed in compliance with local regulations.
BWT AQUA Flex
Inlet
Outlet
200 litres
14 mm hose / ½” inside / 1” outside
¾” outside thread
600 litres
14 mm hose / ½” inside / 1” outside
¾” outside thread
1,000 litres
14 mm hose / ½” inside / 1” outside
¾” outside thread
If the connection is too small, there is a risk of outage on the plant due to lacking water
pressure/amount. In general, pressure losses should be minimized.
Important!
Totally desalinated water can accelerate corrosion. Therefore, always use corrosions-
proof piping for the permeate, e.g. stainless steel or PVC pipe.
Electrical Connections
Note!
The electric connections must be made in compliance with local regulations.
The electric connection to the BWT AQUA Flex BWT AQUA Flex reservoir must be as follows:
All internal connections in the BWT AQUA Flex, the pump, recirculation system and UV is connected
from the manufacturer. It is therefore only the power that have to be connected to a supply
connection, which should be done afterwards.
Electric connection
BWT AQUA Flex 200, 600, 1000
Voltage [V]
1 x 230 V
Net
TN-S
Frequency [Hz]
50 Hz
Power [A]
4.5A
Power consumption [kW]
0.85 kW
Summary of Contents for Aqua Flex T 1000
Page 1: ...BW T Aqua Flex T 200 1000 Reservoir Installation and operating manual ...
Page 17: ...EN 17 P I diagram without options ...
Page 18: ...EN 18 P I diagram with options ...
Page 19: ...EN 19 Layout drawing without Options ...
Page 20: ...EN 20 Electrical connections ...
Page 21: ...EN 21 ...
Page 24: ...EN 24 Spare parts drawing without options ...