Alarms pins as Analogue Outputs
When the alarm
Type
is set to be
Analog Out
, the alarm pin will report the status parameter
selected in
Source
as an analogue voltage on the alarms pins. This setup is typically used
to connect the unit to remote control equipment (also known as telemetry interfaces). The
Souce
can be set to any of the following parameters:
Fwd Power
,
Rev Power
,
PA Volts
,
Aux
Volts
,
Peak Modulation
,
PA Temp
,
RF Mute
.
Use the following equation to translate voltage levels into parameter values:
CurrentValue
=
V
Out
∗
1.2
∗
NominalValue
5
(8.1)
Where:
VOut
is the voltage on the pin in Volts.
NominalValue
is defined in the following table:
Parameter
NominalValue
FWD Power
For TX50 = 50Watts
For TX300 = 300 Watts
...
REV Power
Same as FWD Power
PA Volts
For TX5 = 15 Volts
For TX25 and TX50 = 24 Volts
For TX300 or greater = 48Volts
Aux Volts
15 Volts
Peak Mod
100 kHz
PA Temp
100°C
*RF Mute
* This parameter does not use the above equation.
Its representation is:
If RF Mute = On, VOut = 5 Volts
If RF Mute = Off, VOut = 0 Volts
For example, if the measured Voltage level is 4.166 Volts on a TX50 reporting Forward Power,
the actual current value will be:
Power (watts)= (4.166*1.2*50)/5 = 49.992 Watts (Approx. 50 Watts)
8.5
System
8.5.1
Date
System Date. This is backed up by an internal battery.
70
Summary of Contents for TX V2
Page 7: ...10 2 5 TX600 V2 86 10 2 6 TX1000 V2 87 10 2 7 TX1500 V2 87 10 2 8 TX2500 V2 88 7...
Page 8: ...Part I Introduction 8...
Page 16: ...4 Front and Rear Panels 4 1 1U TX5 TX30 TX50 16...
Page 17: ...4 2 2U TX300 TX600 17...
Page 18: ...4 3 2U TX1000 TX1500 18...
Page 19: ...4 4 3U TX2500 19...
Page 24: ...Part II Initial Setup and connections 24...
Page 31: ...Part III System Configuration 31...
Page 78: ...Part IV Troubleshooting 78...