8.3.2
Action
Selects what the trigger will do when it is detected. Options are:
Frequency Up
,
Frequency
Down
,
Power Up
,
Power Down
,
RF Mute
,
Switch to Int MPX
,
Switch to Ext MPX
,
Switch to Mono
,
Switch to Stereo
,
Reboot
.
Frequency Up
,
Frequency Down
,
Power Up
,
Power Down
and
Re-
boot
will perform the action on falling edges of the signal at the trigger pin.
RF Mute
acts
based on voltage levels.
RF Mute
will be engaged for as long as the trigger signal is pulled
low and unmute when the signal is high.
Note that the RFMute pin (Pin 2) mutes the unit unconditionally. (Triggers set to RFMute will
not be able to unmute the unit if this pin is connected to ground).
8.3.3
Send e-mail
Selects if an e-mail will be sent when the trigger is fired. Make sure that the unit is connected
to the network and that E-mails have been set up correctly
System
⇒
to use this fea-
ture.
8.3.4
(ON) Message
Sets the message that will be sent when the Trigger changes to ON. This parameter accepts
text up to 300 characters.
Sample e-mail:
”Trigger 1 transitioned to ON.
Equipment: TX-V2, Serial Number #8790
Location:
Local IP Address: 192.168.5.31
If you require off-air emergency technical support, please contact the BW Broadcast 24/7
support team:
International Phone: +44 208 2530295
US Toll Free: 1-888-233-1663
Email: [email protected]
Please note that this is an automatic email alert generated by a BW Broadcast TX-V2. To pre-
vent further emails please clear the cause of the alarm or turn off alarm emails on the TX-V2’s
control system.”
66
Summary of Contents for TX V2
Page 7: ...10 2 5 TX600 V2 86 10 2 6 TX1000 V2 87 10 2 7 TX1500 V2 87 10 2 8 TX2500 V2 88 7...
Page 8: ...Part I Introduction 8...
Page 16: ...4 Front and Rear Panels 4 1 1U TX5 TX30 TX50 16...
Page 17: ...4 2 2U TX300 TX600 17...
Page 18: ...4 3 2U TX1000 TX1500 18...
Page 19: ...4 4 3U TX2500 19...
Page 24: ...Part II Initial Setup and connections 24...
Page 31: ...Part III System Configuration 31...
Page 78: ...Part IV Troubleshooting 78...