Use
and operation
34
Translation of the Original Operating Manual
6.2.2
Switching the machine off
1.
Close the dosing gate (see Chapter 6.1.1.1
“Operating elements and controls on the control panel”,
Figure 4). Read the position of the gate at the gate indicator (see “Fig. 4-3: Dosing gate opening
width
2.
Wait until the blower is completely empty.
3.
Switch off the PTO shaft drive of the tractor.
Refer to the operating manual of the tractor for all information on how to switch off the PTO
shaft drive of the tractor.
4.
Flip the lever of the Bowden cable (see Chapter 6.1.2
The machine is switched off.
The blower will coast for up to 3.5 minutes until the impeller has come to a complete