Page 40 of 106
INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
KENDO.30LIGHT-KENDO.30LIGHTFI
7105-M002-0_B
THE MANUFACTURER DOES NOT
ACCEPT ANY DAMAGE RESULT-
ING FROM THE FRAILURE TO
OBSERVE THE ABOVE INSTRUC-
TION, AND SUCH FAILURE
COULD INVALIDATE THE WAR-
RANTY!!
Fig. 46
IN ORDER TO ALLOW A LONGER
LIFE OF THE FILTER AND OF ALL
MOVING PNEUMATIC DEVICES,
YOU HAVE TO MAKE SURE THAT
THE SUPPLIED AIR IS:
• EXEMPT FROM THE LUBRICAT-
ING OIL OF THE COMPRESSOR;
• EXEMPT FROM HUMIDITY;
• EXEMPT FROM IMPURITY.
• Periodically, with a frequency of at least once a month,
lubricate the arms of the bead breaking rolls.
• Immediately replace worn parts, bead breaking rolls,
assembly tools, feeler pins.
• Every
week
and/or when necessary, top up the oil tank
using the filler hole provided closed by a cap or screw
on the lubricator filter.
N.B: This operation should not be carried out by
unscrewing the cup of the lubricator filter.
• The use of synthetic oil might damage the pressure
regulator filter.
• At regular intervals, (at least every 100 working hours)
check reduction gear (
Fig. 46 pos. 1
) lubricating oil
level. Such operation must be effectuated removing the
plug (
Fig. 46 pos. 3
), positioned on the provided hole
prearranged on the frame, and removing the plug po-
sitioned on reduction gear (
Fig. 46 pos. 2
).