INSTRUCTION, USE AND
MAINTENANCE MANUAL
Page 10 of 36
GB
8.0 WORKING ENVIRONMENT CONDI-
TIONS
The machine must be operated under proper condi-
tions as follows:
• temperature: 0° + 55° C
• relative humidity 30 - 95% (dew-free)
• atmospheric pressure: 860 - 1060 hPa (mbar).
The use of the machine in ambient conditions other
than those specified above is only allowed after prior
agreement with and approval of the manufacturer.
8.1
Working position
In
Figure 4
it is possible to identify working positions
A
and
B
.
Position
A
is the main position for wheel fitting and
removal with the mandrel, while position
B
is ideal to
follow wheel bead breaking operations.
Working in these positions allows better precision and
speed during operating phases as well as greater safety
for the operator.
8.2
Installation space
Fig. 4
USE THE MACHINE IN A DRY AND AD-
EQUATELY LIT PLACE, POSSIBLY INDOORS
OR ANYWAY IN A ROOFED AREA, THIS PLACE
MUST BE IN COMPLIANCE WITH APPLICABLE
SAFETY REGULATIONS.
The location of the machine requires a usable space as
indicated in
Figure 4
. The positioning of the machine
must be according to the distances shown. From the
control position the operator is able to observe all the
machine and surrounding area. He must prevent unau-
thorized personnel or objects that could be dangerous
from entering the area.
The machine must be fixed on a flat floor surface,
preferably of cement or tiled. Avoid yielding or irregu-
lar surfaces.
The base floor must be able to support the loads
transmitted during operation. This surface must have
a capacity load of at least 500 kg/m².
The depth of the solid floor must be sufficient to guar-
antee that the anchoring bolts hold.
8.3
Lighting
The machine does not require its own lighting for
normal working operations.
However, it must be placed in an adequately lit envi-
ronment.
For correct lighting, use lamps having total power
800/1200 Watt as envisaged by UNI 10380.
9.0 ANCHORING SYSTEM
The packed machine is fixed to the support pallet
through the holes prearranged on the frame. Such
holes can be used also to fix the machine to the ground,
through floor anchor small blocks (excluded from sup-
ply). Before carrying out the definitive fixing, check that
all the anchor points are laid down flat and correctly
in contact with the fixing surface itself. If not so, insert
shimming profiles between the machine and the fixing
lower surface, as indicated in
Fig. 5
.
Fig. 5
a
= 762
b
= 410
• Execute 4 holes with 10 mm diameter on the floor
by the holes on the bottom floor;
• insert the small blocks (excluded from supply) into
the holes;
• fix the machine to the ground with 4 M8x80 mm
screws (excluded from supply) (
Fig. 5 ref. 1
) (or
with 4 8x80 mm stud bolts (excluded from supply)).
Tighten the screws with an approximate tightening
torque of 70 Nm.
7300-M023-0_B
HP441S.XX - HP441S.XXFI
HP441SQ.XX - HP441SQ.XXFI