Fire arrestor service
Uncleaned muffler will increase noise and affect the engine’s running.
Clean and maintain the fire arrestor regularly to make sure the generator
works normally.
The fire arrestor needs cleaning frequently if you use the generator in very
dirty conditions, or replace the fire arrestor if necessary.
• Before cleaning the fire arrestor make sure the generator is OFF
• Before the check and maintenance of the fire arrestor, make sure the
machine is cool, otherwise it will cause scalding by the hot muffler.
1.
Remove the M6 screws and open the muffler cover.
2.
Remove two M4 screws on the fire arrestor.
3.
Take down the fire arrestor as per the following figure.
4.
Check the fire arrestor, clean or replace it if necessary.