Installation | 5
0870572700_RD0200-0360A_-0003_IM_en
11 / 28
• To reduce the maintenance effort and ensure a long product lifetime we recommend
the following cooling water quality:
Hardness
mg/l (ppm) < 90
Properties
Clean & clear
PH value
7 … 8
Particle size
µm
< 200
Chloride
mg/l
< 100
Electrical conductivity
µS/cm
≤
100
Free chloride
mg/l
< 0.3
Materials in contact with the cooling water Stainless steel, copper and cast iron
NOTE
Water hardness unit conversion.
1 mg/l (ppm) = 0.056 °dh (german degree) = 0.07 °e (english degree) = 0.1 °fH (french
degree)
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.
For oil type and oil capacity see
.
1
4
MAX
MIN
3
2
Busch Oil
Check oil level
1x o-ring, part no.:
see "Service kit" (Spare Parts)
Summary of Contents for R 5 RD 0200 A
Page 27: ...Note ...