5.1 Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
~10 cm
~30 cm
~10 cm
~5 cm
~30 cm
~10 cm
~10 cm
~10 cm
~20cm
~30 cm
Standard version
Version with cooling air deflector (optional)
• Make sure that the environment of the machine is not potentially explosive.
• Make sure that the ambient conditions comply with the
.
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
• Even 0.5° in longitudinal direction, in case of a level switch is being used in.
• Check the oil level, see
• Make sure that all provided covers, guards, hoods, etc. are mounted.
Version with water-oil heat exchanger:
• Make sure that the cooling water complies with the requirements, see
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.