Installation | 5
0870135611_MM1202_MM1322AP_A0001_IM_en_MD
9 / 24
For oil type and oil capacity see
.
SCH
Mink
B
U
MAX
MIN
1
2
3
Bu
sc
h
O
il
4
5
6
4 mm hex key
Check oil level
The oil level should stay constant over the lifetime of the oil. If the level does fall, this
indicates a leak and the machine requires repair.
5.4 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• The electrical installation must comply with applicable national and international
standards.
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.
• Busch recommends installing a D-curve circuit breaker.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
• Electrically connect the motor.