9 | Decommissioning
16 / 24
0870135611_MM1202_MM1322AP_A0001_IM_en_MD
Busch will only accept machines that come with a completely filled in and legally bind-
ing signed ‘Declaration of Contamination’ (form downloadable from
).
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
• Disconnect all connections.
If the machine is going to be stored:
• See
9.1 Dismantling and Disposal
• Drain the oil.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency!
• The exclusive use of Busch genuine spare parts and consumables is recommended
for the correct functioning of the machine and to validate the warranty.
Spare part
Description
Part no.
Oil fill plug (=Venting
valve)
Includes appropriate seal ring
0543 107 407
Oil sight glass
0583 000 001
Seal ring
For oil sight glass
0480 000 271
Oil drain plug
Includes appropriate seal ring
0415 134 870
Seal ring
For oil drain plug
0482 137 352
Inlet flange lower part
Includes non-return valve
0916 000 670
Inlet screen
0534 000 041
Safety valve
Quote in your order also the ultimate
working pressure of the machine
On request
If other parts are required:
• Contact your Busch representative for the detailed spare parts list.