5 | Installation
8 / 24
0870135611_MM1202_MM1322AP_A0001_IM_en_MD
5.2 Connecting Lines / Pipes
WARNING
Rotating Parts.
Risk of severe injury!
• Do not operate the machine without suction / discharge connection installed.
• Remove all protective covers before installation.
• Make sure that the connection lines cause no stress on the machine‘s connection; if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least
as large as the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid
a loss of efficiency. Seek advice from your Busch representative.
5.2.1 Suction Connection
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
• Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– Without connection. The inlet gas is sucked from the ambient air of the machine.
Depending on the specific order, other connection dimensions may apply.
• Make sure that the gas is drawn without obstruction.
5.2.2 Discharge Connection
Connection size(s):
– G2
Depending on the specific order, other connection dimensions may apply.
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.