Transport in unpacked state

The vacuum pump is fastened to the pallet with fixing pins:

u

Unscrew the fastening nuts underneath the pallet.

CAUTION

Do not work, walk or stand under suspended loads.

CAUTION

Please check out the weight of the vacuum pump before lifting it up
(see "Technical Data").

Use adequate lifting gear for this.

CAUTION

In the case of a vacuum pump filled with oil, you ensure that the
angle of inclination of the vacuum pump at the time of rise does not
exceed 5° compared to the horizontal. In the event of too important
slope (> 5°), risk of oil leakage in the workspace.

NOTE: The suspension eyes are located at about the center-of-gravity
of the vacuum pumps. If the vacuum pumps are equipped with acces-
sories that could influence the center-of-gravity, this must be taken
into account when lifting and a belt must additionally be attached to a
specific point.

Lifting for DP 0600 C

l

Fasten the hoist to the suspension eye(s) on the cylinder

l

Use a hoist that is equipped with a hook and safety lock

l

Lift the vacuum pump

If the vacuum pump is fastened to several pallets with fixing pins:

Unscrew the fixing pins in the base frame

Before each transport requiring a means of adapted lifting, control the
slope of the vacuum pump (< 5°).

The packaging material must be disposed of in accordance with local
and national regulations.

This handbook is contained in the delivery package.

For future transportation :

l

Seal all open connections with protective caps (to prevent
penetration of dirt and water)

l

Secure loose cables

l

Protect from shock

l

Drain all process and operating media

l

Secure vacuum system firmly before transporting (e.g. bolt to
several pallets)

l

Use a lift truck to move and set the vacuum system down

Storage

Temporary storage

l

Make sure that the intake and exhaust flanges are closed (put on
the protective caps included in the delivery package of the vacuum
pump)

l

Store the vacuum pump

if possible, the vacuum pump should be stored in its original
packaging,

indoors,

dry,

in a dust-free and

vibration-free room

Removal of the pump

Before starting a vacuum pump that has been stored outside the buil-
ding for a while, the vacuum pump must be moved to a room with
ambient temperature, where it should rest for a day.

Preservation

If the vacuum pump will be exposed to unfavourable ambient condi-
tions (for example, aggressive environment, frequent temperature
changes), begin immediately with preservation work on the vacuum
pump.
In the case of favourable ambient conditions, perform preservation
work on the vacuum pump if a storage period of more than three
months is planned.

l

Make sure that all openings are hermetically sealed; use adhesive
tape to fasten loose parts (seal rings, flat seals, etc.).

NOTE

: VCI is the abbreviation for “volatile corrosion inhibitor”. The

VCI molecule is an organic corrosion inhibitor in the vapour phase.
Integrated in various carriers such as film, cardboard, paper, foam, li-
quid and powder, it protects the parts against corrosion as a result of
its action in the vapour phase. However, VCI packaging can attack syn-
thetic surfaces and surfaces of other elastomers. If in doubt, please
contact your nearest distributor. VCI packaging provides several years
of protection against corrosion, even under the harshest of conditions:
overseas shipment, extended storage before use.

l

Wrap the vacuum pump in a VCI film

l

Store the vacuum pump

if possible, the vacuum pump should be stored in its original
packaging,

indoors,

dry,

in a dust-free and

vibration-free room

Start-up of the vacuum pump after storage:

l

Make sure that all protective elements, stoppers or adhesive tapes
attached before preservation have been removed

l

Switch on the vacuum pump in the sequence described in the
chapter “Installation and start-up”

DS 3010 E

Storage

0870771509 (En)

Page 9

Summary of Contents for COBRA DS 3010 E

Page 1: ...Screw Vacuum Pumps and Roots Pumps COBRA DS 3010 E Standard version Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870771509 181024 Origin...

Page 2: ...am 19 Weekly 19 Monthly 19 Yearly 19 Every 16 000 hours of operation at the latest after 4 years 20 Lock Out Tag Out procedure 20 Safety Lockout procedure 20 Checking the oil 20 Checking the oil level...

Page 3: ...3010 E 0870771509 En Page 3 DP IN OUT ESS MSH PTB RC COBRA DS 3010 E DP Backing vacuum pump DP 600 C ESS Emergency stop switch IN Inlet MSH Main switch OUT Discharge to silencer PTB Pump terminal box...

Page 4: ...le of cylinder DGR2 Regulating valve dilution gas end of cylinder ECO Power connection EV Expansion vessel FME Flow meter nitrogen FS 1 Flow switch cooling liquid FS 2 Flow switch cooling water HE Hea...

Page 5: ...rogen system NC Nitrogen supply OSG 1 Oil level indicator DP OSG 2 Oil level indicator DP OSG 3 Oil level indicator MB OSG 4 Oil level indicator MB PGI Process gas inlet PGO Process gas outlet PRV Nit...

Page 6: ...id is above 100 C The pump will stop immediately after the emergency alarm ring a direct cooling water circuit in the motors in the cylinder covers A and B side of WZ rotary lobes vacuum pump and COBR...

Page 7: ...and instruct his personnel accordingly Local regulations regarding the motors and electric control elements must be observed when installing the pump in potentially explosive environments The maintena...

Page 8: ...l Switch off the water inlet first then outlet and nitrogen quick connections l Put the label or warning board Maintenance processing on or next to the pump Safety Lockout procedure l Take off the lab...

Page 9: ...ges are closed put on the protective caps included in the delivery package of the vacuum pump l Store the vacuum pump if possible the vacuum pump should be stored in its original packaging indoors dry...

Page 10: ...ills the requirements for assembly dismantling l Make sure that no temperature sensitive parts for example of plastic wood cardboard paper electronic parts come into contact with the hot surfaces of t...

Page 11: ...e that the regulations of the Electromagnetic Compatibility Directive 2014 30 EU as well as standard EN norms safety directives and especially local and national regulations are observed this is the r...

Page 12: ...g direction it can be destroyed even if this is the case for only a short moment Make sure that the vacuum pump is connected correctly before switching it on l Determine rotation sense of the motor by...

Page 13: ...ically tight NOTE It is easier to switch on the vacuum pump with cold oil when the intake line is not closed or when the intake flange is not covered by a rubber plate l Start the vacuum pump If the i...

Page 14: ...um pump at the time of rise does not exceed 5 compared to the horizontal In the event of too important slope 5 risk of oil leakage in the workspace l Before each transport requiring a means of adapted...

Page 15: ...issible number of startings per hour 6 As far as temperature is concerned the pump is suitable for continuous duty at any pressure between atmosphere and ultimate pressure The vacuum pump is tight dow...

Page 16: ...ent Level Time Before and DP Idle are idle CAUTION LL Mode Off is not recommended for Load Lock cyclic pumping due to the current load and the mechanical stress with full speed l LL Mode Auto u The mo...

Page 17: ...XTERN DS 3010 E Standard operational time chart 0870771509 En Page 17 LCD start or Remote start tool pump Pump speed Booster Dry pump Pump ready pump tool Process on tool pump 1 Cold start 2 MB on del...

Page 18: ...sec 2 MB on delay 30 sec Standard operational time chart DS 3010 E Page 18 0870771509 En Pump speed Booster Dry pump Pump ready pump tool Chamber open close gate valve on off 1 Cold start 2 MB on del...

Page 19: ...oling liquid and oil levels according to the chapters Checking the oil level and Checking the cooling liquid level open the power box cover and check that the FDP1 thermal relay is on manual reset pos...

Page 20: ...the condensate drain l Drain the oil see Draining the oil WZ MB rotary lobes vacuum pump If the oil level does not reach the target circle u Top up with oil see Refilling oil If the oil level exceeds...

Page 21: ...gs again and drain any remaining oil l Check that no metal swarf sticks to the magnet of the drain plug clean if necessary l Refit the oil drain plugs and tighten up l Dispose of the used oil in compl...

Page 22: ...of cylinder upper plate l Screw on the cooling liquid filler cap again l If liquid has run on to the outside surfaces of the vacuum pump wipe it off Draining the cooling liquid l Make sure that the v...

Page 23: ...nto pores openings and other internal parts of the vacuum pump There is a health hazard when dismantling the vacuum pump There is also a danger to the environment Prior to shipping the vacuum pump mus...

Page 24: ...ot be dismantled drain the oil u dispose of the oil according to local environmental protection regulations drain the cooling liquid u dispose of the cooling liquid according to local environmental pr...

Page 25: ...to hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the...

Page 26: ...of informative nature only Respect the procedure of filling the cooling liquid Quantity Zitrec M 25 already mixed ready to use DS 3010 E approx 26 litres CAUTION The proportion of pure glycol and wate...

Page 27: ...5 15 Nominal motor speed DP 60 Hz min 1 3600 Nominal motor speed MB 90 Hz min 1 5400 Noise level EN ISO 2151 50 Hz 60 Hz dB A dB A 75 Ambient temperature C F 0 40 32 104 Maximal counter pressure Disch...

Page 28: ......

Page 29: ...equipment and following the standards Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2008 Safety of machinery Safety dis...

Page 30: ...Note...

Page 31: ...Note...

Page 32: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...