7 | Maintenance
26 / 36
0870557375_NC2000B_VR_Ex_A0002_IM_en
7.2 Oil Level Inspection
• Shut down the machine.
• When the machine is stopped, wait 1 minute before checking the oil level.
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
3 mm
MAX
MIN
3 mm
MAX
MIN
3 mm
Oil sight glass on motor side
Oil sight glass on suction side
• Fill up if necessary, see
Oil Filling [
►
14]
.
7.3 Oil Change
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.
1
2
6
4
5
3
Oil draining at the motor side
Drain pan
Magnetic
plug
Cleaning cloth