94
of 175
7.4.26 Evaluation trapezoid window X1 (Slot 55)
Slot
Index Description
Value
Meaning of value
Type
Len R/W
55
0
Not possible
-
-
X
55
1 .. 9 Reserved
-
-
X
55
10 ... Trapezoid X1
off/on
0
1
off
on
U16
2
RW
55
11
Trapezoid X1
limit Xmin
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
12
Trapezoid X1
limit Xmax
Note
: At the end, entry
must be adopted
through index 17.
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
13
Trapezoid X1
Y limit top left
Note
: At the end, entry
must be adopted
through index 17.
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
14
Trapezoid X1
Y limit top right
Note
: At the end, entry
must be adopted
through index 17.
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
15
Trapezoid X1
Y limit bottom left
Note
: At the end, entry
must be adopted
through index 17.
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
16
Trapezoid X1
Y limit bottom right
Note
: At the end, entry
must be adopted
through index 17.
between
-9999999.0 and
9999999.0
Float value
Float according to
IEEE754
FLT
4
RW
55
17
Trapezoid X1
copy the limits
Note
: Values entered
into indices 11 - 16 are
adopted
EVENT
Writing an arbitrary byte
initiates action
U8
1
WO