13
of 175
3 Technical Data
3.1 PROFIBUS DP system data
Number of devices or modules
126 with repeaters
Transmission medium
Cu cable to IEC 61158
Max. bus segment length
100 m to 1200 m (dependent on baud rate/cable)
Data transfer rates
9.6 kBaud to 12 MBaud (dependent on cable)
You will find further information about PROFIBUS DP at:
3.2 Model 9307 device data
Supported transfer rates
9.6 kBit/s
187,5 kBit/s
3000 kBit/s
19.2 kBit/s
500 kBit/s
6000 kBit/s
93.75 kBit/s
1500 kBit/s
12,000 kBit/s
Bus connector
9 pin SUB-D socket (female)
ID number
0D0D Hex
GSD file
BUR_0D0D.gsd
Adress range
1 to 126 [default adress 2]
3.3 Electrical safety
Reverse voltage protection
Yes
Air clearance/leakage paths
To DIN EN 61010-1
Electrical isolation
Between fieldbus and internal electronics
Withstand voltage
DC 500 V