27
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
period of more than
60
sec, the burner
will detect that there is no stable burning
process going on and will extinguish the
burner and attempt to reignite.
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the
menu.
Use this menu to conduct
fan operation
test
.
This menu allows
you to select
maximum boiler
temperature. In
other words, the
maximum temperature to heat the boiler
on which the burner has been installed.
The maximum value for this setting is
85°С
. Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the menu.
You can control the
fan in real time,
without confirming
anything, using only
the navigation arrows.
Important. This menu is for
installers only and it is active
and visible only if the controller
is in „Standby” mode.
Test EFan Speed
Use this menu to
test the fan exhaust
(if installed). You
can control the fan
in real time, without
confirming anything, using only the
navigation arrows. Use the
button
to open the next page of the menu.
This menu allows
you to check the
operation of the
various pellet
b u r n e r
components. Using the navigation
arrows, you can turn on and off the
various components and each time the
respective components is being activated
a checkmark will appear in front of its
name. Use the „
Enter
” button to select
the individual components.
Description of components:
1)
FF
– Fuel Feeder – main auger
2)
BF
– Burner Feeder – internal burner
auger / feeder
3)
CH
– Central Heating pump
4)
DHW
– Domestic Hot Water pump
5)
Ign
– Ignition
6)
CM
– Cleaning Motor
Important. This menu is for
installers only. It is active and
visible only if the controller is
in "Standby".
10. SETTING OUTPUT MODES OF
OPERATION OF THE PELL PELLET
BURNER
CAUTION! You must use gas
analyzer when setting the
burner.
The Pell pellet burner is equipped with
three-step output adjustment and their
setting depends on the boiler and heat
requirements of the heating installation.