English
General safety requirements
`
`
Read these directions for use carefully before using.
`
`
Keep these directions for use where they will be
accessible for all users.
`
`
Failure to comply with the directions for use shall
render all warranty conditions null and void and
may lead to personal injury and material damage.
`
`
The instrument must only be used by qualified
skilled employees.
`
`
The instrument is designed for use in industry, labo-
ratories and science. The instrument is not suitable
for any application in private or public spaces.
Safety instructions before using
`
`
Follow the manufacturer‘s instructions and safety
instructions of the medium you are filling.
`
`
Damage to the respiratory tract and other organs
due to escaping or off-gassing media. Fill only in
ventilated rooms or under a suitable exhaust hood.
Wear appropriate protective clothing.
`
`
The instrument is not suitable for filling off combus-
tible liquids.
`
`
The instrument must only be used within the
confines of applicable material resistance and for its
designated purpose. Any other type of use will affect
the warranty/guarantee.
`
`
Do not use any force when operating the instru-
ment.
Safety instructions during and after use
`
`
The instrument is suitable for indoor use and ma-
nual operation.
`
`
Pump with manual operation. Not suitable for
continuous operation.
`
`
Pay attention to have sufficient space above during
the filling process (minimum height: height of the
maximum extended 20 cm).
`
`
The instrument is not suitable for cleaning in a
dishwasher.
Layout and function
`
`
The instrument is made of non-conductive material
(PP, PVC) and is suitable for filling acids and alkalis
(pay attention to the chemical resistance).
`
`
The instrument is suitable for filling from cont-
ainers with a capacity of 60 - 1000 l into smaller
containers.
`
`
The instrument can be used with a discharge tube
with maximal length of 1,20 m.
`
`
The instrument is maintenance-free and suitable at
a temperature range from 0 to 40 °C.
Point out any damage in the packaging to the freight
forwarder/supplier immediately.
Assembly
1. Screw the discharge hose
onto the riser pipe
.
2. Guide the barrel screw connection (accessory; not
included in delivery) and riser pipe
with the
discharge hose
into the container and screw it
together finger-tight.
3. If necessary adjust the riser pipe.
Safe filling
1. Hold the discharge hose in the filling container.
2. Open the shut-off valve
on the discharge hose.
3. Activate the piston rod
by using the handle
and fill off the liquid.
CAUTION!
Escaping liquids due to falling over or tipping of
the instrument. Bodily injury due to escaping liquid
and damage to the instrument.
`
`
Ensure sufficient stability of the instrument.
`
`
Shut down and secure the instrument immedi-
ately.
`
`
Contact the dealer or manufacturer.
NOTE!
Pump and valves can be damaged or plugged by
dirt particles.
`
`
Do not fill off any polluted media.
`
`
Rinse the pump with a pH-neutral medium.
WARNING!
Some liquid will continue to run while the dischar-
ge hose is being screwed on. Bodily injury due to
escaping liquid.
`
`
Close the shut-off valve
on the discharge
hose before mounting.
NOTE!
Ensure to use a fitting thread (see accessories).
`
`
Screw the thread by hand and without any