30
Disassembly
12.
DISASSEMBLY
12.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment/device.
▶
Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
Risk of electric shock.
▶
Before reaching into the device, switch off the power supply
and secure to prevent reactivation.
▶
Observe applicable accident prevention and safety regulations
for electrical equipment.
WARNING!
Risk of injury from improper disassembly.
▶
Disassembly may be carried out by authorized technicians only
and with the appropriate tools.
Risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶
Secure system from unintentional activation.
▶
Following disassembly, ensure a controlled restart.
12.2. Disassembly the Pneumatic
Control Unit
Procedure:
1. Pneumatic connection
DANGER!
Risk of injury from high pressure in the equipment/device.
▶
Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
→
Loosen the pneumatic connection.
→
Series 20xx:
Loosen the pneumatic connection between Pneumatic
Control Unit and actuator.
2. Electrical connection
DANGER!
Risk of electric shock.
▶
Before reaching into the device, switch off the power supply
and secure to prevent reactivation.
▶
Observe applicable accident prevention and safety regulations
for electrical equipment.
Circular plug-in connector:
→
Loosen the circular connector.
english
Type 8697
Summary of Contents for 8697
Page 32: ......