background image

PlusConnect

™ GatesAir

 Sigma Installation and Operation Manual   

 

 

 

             10 

 

 

Channels 

or 

Commands 

tab, as appropriate: 

 

1.

 

Within any of these tabs, click the button at the right edge of the 

Source 

field to change a 

channel’s

 

assignment from a traditional I/O channel to a Plus-X channel. 

2.

 

When the Source dialog appears, select the 

Plus-X 

radio

 

button

 

and choose the PlusConnect device 

from the list. 

3.

 

Select the PlusConnect channel you wish to use in place of this I/O channel. 

4.

 

Click 

OK

 

Once mapped and saved, the PlusConnect channel will appear on the front panel of the ARC Plus, in 

AutoPilot, on the ARC Plus web page, and will be accessible via the ESI or RSI. 

 

Setting up Labels, Limits and Alarms

 

Labels, limits and alarms for PlusConnect parameters are set up in AutoLoad Plus. The process is the same 
as for limits and alarms of other ARC Plus channels. Refer to the ARC Plus manual for information on 
channel configuration. 

 

Important! Because operation preferences vary so widely, no alarms are pre-configured within the 

PlusConnect channels. You must use AutoLoad Plus to set up alarms for the PlusConnect channels. 

 

Creating a PlusConnect Custom View in AutoPilot

 

 
 
 
 
 
 

 

 
 
 
 
 
The easiest way to monitor your PlusConnect parameters is by creating a Custom View in AutoPilot 

using a pre-built template specific to your transmitter model. In order to use templates, you must map 

 

PlusConnect Custom View Template for the GatesAir Sigma transmitter

 

 

Summary of Contents for PlusConnect GatesAir Sigma

Page 1: ...Installation and Operation Manual REV D PlusConnect GatesAir Sigma Installation and Operation Manual ...

Page 2: ...Panel Indicators 2 HardwareConfiguration 3 Installation 5 Software Configuration 6 Setting up Labels Limits and Alarms 8 Creating a PlusConnect Custom View inAutoPilot 9 Operation 10 Troubleshooting 11 Getting Help 11 Warranty 11 Copyright 2015 2021 Burk Technology Inc ...

Page 3: ...he PlusConnect is part of the Plus X family of Ethernet I O products designed for the ARC Plus Important The PlusConnect operates in conjunction with an ARC Plus system Be sure to complete configuration of the ARC Plus before adding the PlusConnect to the system Compatibility TransmitterCompatibility Model Compatibility PlusConnect GatesAir Sigma All GatesAir Sigma transmitter models Transmitter m...

Page 4: ...rrent Updates are available at www burk com Unpacking The PlusConnect ships with thefollowing PlusConnect unit AC Power cord 10 Shielded CAT5 cable 10 DB9F to DB9F serial cable Front Panel Indicators Indicator State Description Power LED On Power is on Power LED Off Power is off Link LED On ARC Plus to PlusConnect connection isgood Link LED Off ARC Plus to PlusConnect connection isdown Front panel...

Page 5: ... Config button on the rear panel of the PlusConnect unit Holdthe button in until the Power LED begins to blink The Power LED will stop blinking when the unit has completed restoring default settings 5 Enable Telnet on your Windows 7 or Windows 8 computer if not already enabled using the following steps Click Start Control Panel Click Programs and Features Click Turn Windows features on or off In t...

Page 6: ...2 IP Address The IP address you want to assign to the PlusConnectunit 3 Subnet The subnet mask for your LAN 4 Gateway The gateway for your LAN 7 ARC Plus IPAddress The IP address of your ARC Plusunit 8 Plus XPort The Plus X port number configured on your ARC Plus typically 45000 9 Set Unit Name The PlusConnect unit name Once the settings have been saved the PlusConnect can be connected to the targ...

Page 7: ...s to complete all steps of this process please contact your system administrator 2 Go to www burk com downloads select the ARC Plus tab then scroll down to the PlusConnect section 3 Download and install the Burk Firmware Loader Download the PlusConnect GatesAir sigma firmware 4 Go to www burk com downloads and select the ARC Plus tab then scroll down to the PlusConnect section 5 Download and save ...

Page 8: ... J7 also called HP1 and HP2 on the Sigma Transmitter To ensure that your transmitter is configured to interface with the PlusConnect you should first verify the following Sigma CD Transmitter software and firmware revisions GUI Program Software for Windows GUI Version 5 0 0 or higher Main Controller Firmware Version 3 0 or higher Amplifier Interface Board Firmware Version 1 11 or higher IPA Module...

Page 9: ...nnect select System I O board switches S4 and S5 as shown in the image below from the GatesAir software instruction guide Both S4 and S5 dipswitches should only have positions 3 and 4 ON Now apply power to the PlusConnect unit and wait for the green Power LED to illuminate DIP Switch Settings for Direct Computer Connection ...

Page 10: ...usConnect must be added to the ARC Plus site 1 Open AutoLoad Plus and connect to the ARC Plus site to which you are adding the PlusConnect 2 Select that site from the Navigator pane on the left side of the window 3 From the Edit menu select Plus X Devices to open the list of currently configured Plus X Devices 4 Click Add to add the PlusConnect to the site This opens the Plus X Device dialog 5 For...

Page 11: ...tes are available for use with the GatesAir Sigma These custom view templates are optimized for Sigma transmitters with one two or three power amplifier cabinets The names of these specialized custom view templates are PlusConnect GatesAir Sigma 1PA PlusConnect GatesAir Sigma 2PA and PlusConnect GatesAir Sigma 3PA respectively Important PlusConnect channels take the place of normal I O channels If...

Page 12: ...nd will be accessible via the ESI or RSI Setting up Labels Limits and Alarms Labels limits and alarms for PlusConnect parameters are set up in AutoLoad Plus The process isthe same as for limits and alarms of other ARC Plus channels Refer to the ARC Plus manualfor information on channel configuration Important Because operation preferences vary so widely no alarms are pre configured within the Plus...

Page 13: ...t AutoPilot and select the site and the ARC Plus unit you are using If the site has not been created in AutoPilot see Adding Sites in the AutoPilot Instruction Manual available at www burk com downloads 2 Select File Connect A progress dialog will be displayed while the connection to the ARC Plus is being established 3 Open the Custom View Editor by selecting File New Custom View 4 When the Custom...

Page 14: ...els 11 Save the Custom View using the Save icon in the toolbar 12 Close the editor You may then select the Custom View for display inAutoPilot For additional information on creating and editing AutoPilot Custom Views see Creating Custom Views in the AutoPilot Instruction Manual Operation Once the PlusConnect parameters are mapped to ARC Plus channels using AutoLoad Plus accessing the transmitter p...

Page 15: ...repaired or replaced at the option of Burk Technology and returned freight prepaid to the customer Damage due to abuse or improper operation or installation of the equipment or caused by fire or flood or harsh environment is not to be covered by this warranty Damage in shipping is not the responsibility of Burk Technology A return authorization must be obtained before returning any equipment Mater...

Reviews: