8-2
8.2 Filling the Melting Rack Water Jacket
1. Verify all electrical power is removed from unit.
2. Disconnect the supply hose and connect the provided quick connect
coupling to the melting rack discharge hose inlet.
3. Connect house water supply to coupling.
4. Slowly fill melting rack water jacket until water is
seen in the sight tube. Water level should be
maintained between lines as shown on right. Turn
off water supply and disconnect from discharge
inlet.
5. Reconnect discharge hose to melting rack
6. Touch “PREHEAT” from the operator control
panel and verify water level through sight tube.
7. Verify sight tube level, repeat procedure until
proper water level is maintained.
NOTE: Filling the water jacket too rapidly will cause
water spillage from the vent.
CAUTION:
Low water level inside the water jacket may result in heater failure.
NOTE: Visually verify water is circulating through supply and return
hoses. Pump damage may occur if ran dry.