INITIAL SETUP - U3

CAUTION - 

The brewer must be disconnected from the power source throughout the initial setup, except when specified 

in the instructions.

IMPORTANT: 

Brewer must be level and installed on a sturdy structure.

 

 

 

Electrician's and Plumber's Instructions are provided. These instructions should be carefully followed  

 

 

 

before proceeding with initial setup.

 

 

 

Be sure all electrical and plumbing connections are tight.

1.  Open manual fill valve located on the bottom of the brewer. Water should start filling the tank. When water is visible 

in the hot water gauge glass (center spigot), close valve. Approximate time for filling manually is 3 minutes.

CAUTION: 

Never leave brewer unattended while manually filling tank.

2.  Connect the brewer to the power source. Turn "ON/OFF" switch to the "ON" position. Water should finish filling tank 

automatically.

NOTE:

 It is recommended that the "ON/OFF" switch be left in the "OFF" position at the end of the operating day or when 

unattended for a long period of time.

3.  Disconnect the brewer from the power source. Remove front cupola cover for access to thermostat knob and timer. 

On some brewers the thermostat knob is located on the front of the cupola cover.

4.  Turn the thermostat knob clockwise to an approximate 5 o'clock position. Allow 1-1/2 hours for water to heat. Time 

will vary with incoming water temperature.

5.  On initial warm-up, some water may flow thru the overflow spigot due to expansion of the cold water in the tank. 

This will not recur during the use of the brewer and may be avoided on the initial warm-up by drawing off 1/2 gallon 

decanters of water each 15 minutes till brewing temperature is reached.

6.  Brewing cycles may be started whenever water temperature is correct. This condition is indicated by the dial 

thermometer on front of the brewer. Whenever the pointer is in the green, brewer is ready for brewing. The 

recommended brewing temperature is approximately 200

° 

F (93°C). Water temperature may be increased by 

turning thermostat knob clockwise, decreased by turning knob counterclockwise.

7.  When desired temperature is reached, insert funnel support, funnel and funnel cover in position. Be sure 

the water swing spout is over the center of the funnel cover, turn "ON/OFF" switch to the "ON" position, push 

and release "START" and run a brew cycle of hot water only. At the end of this cycle, brewer will be ready for 

checking timer adjustment.

8.  The timer has been preset for a 4 minute cycle. This setting will deliver approximately 3 gallons of water per 

brewing cycle. To increase or decrease amount of water, adjust the timer as required. See 

Adjusting Brew 

Volumes.

9.  Having determined final settings of the thermostat and the timer, replace front cupola cover. Brewer is now 

ready for brewing coffee.

PLUMBING REQUIREMENTS

These brewers must be connected to a cold water system with operating pressure between 20 (.138) and 90  psi (.620 MPa) 

from a 1/2" or larger supply line.  A shut-off valve should be installed in the line before the brewer.  Install a regulator in the 

line when pressure is greater than 90 psi (.62 MPa) to reduce it to 50 psi (.345 MPa).  The water inlet fitting is 3/8" flare.

NOTE - 

Bunn-O-Matic recommends  3/8" copper tubing for installations  from the 1/2" water supply line.  A tight coil of 

copper tubing in the water line will facilitate moving the brewer to clean the counter top.  Bunn-O-Matic does not recom-

mend the use of a saddle valve to install the brewer.  The size and shape of the hole made in the supply line by this type 

of device may restrict water flow.

As directed in the International Plumbing Code of the International Code Council and the Food Code 

Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate 

backflow prevention to comply with federal, state and local codes. For models installed outside the 

U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.

42769  061516

Summary of Contents for SRU/U3

Page 1: ...19 2010 Bunn O Matic Corporation To ensure you have the latest revision of the Operating Manual Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at...

Page 2: ...atements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the war...

Page 3: ...o reduce the risk of electric shock do not remove or open cover No user serviceable parts inside Authorized service personnel only Disconnect power before servicing WARNING Hot Water Use With Care WAR...

Page 4: ...d in applications such as farm houses Access to the service areas permitted by Authorized Service personnel only The A Weighted sound pressure level is below 70 dBA NORTH AMERICAN REQUIREMENTS This ap...

Page 5: ...50 Hz GREEN GREEN L1 L2 L3 are the 3 phases V1 Phase to phase voltage between any 2 phases V2 Phase to neutral voltage any phase to neutral SYSTEM VOLTAGE V1 V2 208 208 120 240 240 139 380 380 220 440...

Page 6: ...or Initial Setup SRUA CE Models require 2 wire grounded service rated 230 voltsac 30amp singlephase 50Hz P1842 SRU Models require 2 wire grounded service rated 208 or 240 volts ac 30 amp single phase...

Page 7: ...for brewing The recommended brewing temperature is approximately 200 F 93 C Water temperature may be increased by turning thermostat knob clockwise decreased by turning knob counterclockwise 7 When de...

Page 8: ...rs depending on the incoming water temperature Some water will flow from the overflow tube during this time due to expansion Draw off a 1 2 gallon of water every 15 minutes during the initial heat up...

Page 9: ...BREW switch until you see three breaks in the water stream from the swing arm and then release the switch Failure to release the switch within two seconds after the third break in the water stream ca...

Page 10: ...sight gauge cleaning brush into the sight gauge glass tube and clean 7 To clean coffee faucet s remove the faucet handle from the faucet and faucet clean out cap Clean faucet with a faucet cleaning br...

Reviews: