24
SERVICE (CONT.)
Condenser Fan
FIG. 12 CONDENSER FAN
Location:
The condenser fan is located inside the main frame
below the compressor assembly.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the 2-pin from the fan to the main wiring
harness.
3. Check for continuity across the fan terminals.
If continuity is present as described, reconnect the
wires to the fan terminals.
If continuity is not present as described, replace the
fan.
Removal and Replacement:
1. Disconnect the dispenser from the power source.
2. Remove the four screws attaching the fan and wire
guard to the mounting bracket.
3. Disconnect the 2-pin connector from the fan to the
main harness.
4. Remove the fan from the wire guard and discard.
5. Install the new fan onto the wire guard..
6. Install fan and wire guard assembly using four
screws previously removed.
7. Reconnect the wiring harness to the new fan.
8. Use wire ties where necessary to secure the wiring
from any moving parts.
9. Reconnect power to the dispenser.
FIG. 13 CONDENSER FAN TERMINALS
P1219
BLU/BLK
WHI
55124 021418