Circulation Pump
FIG. 18 CIRCULATION PUMP
Location:
The Circulation Pump is located on top of the water
bath tank cover.
Test Procedure:
1. Disconnect both spade terminals at the pump.
2. With a voltmeter, place the leads across the harness
side that connected to the pump. The voltage reading
should be 120V ac continuously when dispenser is
powered.
3. Install amp clamp around red/black wire going to
the pump. Meter should display around .36 amps.
4. Visually ensure the pump is moving or circulating
water.
Removal and Replacement:
1. Remove dispense platform for ease of taking out
recirculating pump.
2. Remove left and right side panels.
3. Remove silicone condensation hose out of bath
tank along side recirculating pump.
4. Disconnect pump motor and condenser fan wires
(1/4” spade terminals).
5. Release recirculating pump holding brackets each
side (4 nuts).
6. Lift up on recirculating pump and maneuver out
the right side of the machine.
FIG. 19 CIRCULATION PUMP
RED/BLK to
Compressor Switch
WHI to Transformer