SERVICE (CONT.)
Dispense Handles
FIG. 29 DISPENSE HANDLES
FIG. 30 DISPENSE REED SWITCH
Reed Switches
Magnets
Location:
The dispense handles are located on the lower
outside of the dispenser door.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Remove the access plug from the bottom of the
door and remove the two screws attaching the pull
and hold handle assembly to the mounting bracket.
3. Disconnect the switch from the wiring harness and
remove the reed switch from the block.
4. Source a magnet to test the switch contacts for
closure.
5. With a voltmeter, check across the two terminals
for each dispense switch. Place the magnet near
the switch surface to close the switch contacts.
6. The meter will show 0.00 for continuity and when
the magnet is removed, the switch should return
to an open connection.
If continuity is not present with the test magnet, replace
the reed switch.
If continuity is continuous without the test magnet,
replace the reed switch.
If continuity is present with the test magnet, inspect
the pull and hold handle internal parts for mechanical
operation and magnet for corrosion.
Removal and Replacement:
1. Disconnect the dispenser from the power source.
2. Remove the access plug from the bottom of the
door and remove the two screws attaching the pull
and hold handle assembly to the mounting bracket.
3. Disconnect the switches from the wiring harness
and remove the pull and hold handle assembly.
4. Carefully slide the new handle assembly through
the gasket.
5. Connect the wires for the nitro reed switch to the
connector with white and blue wires.
6. Connect the wires for the still reed switch to the
connector with white and red wires.
7. Insert the handle assembly into the door opening
and secure with two screws previously removed.
8. Re-install the access plug to the bottom of the door.