12
LED Light
(optional)
Press light button to turn the LED light on and off. To toggle between all
the LED color options, press the light button on, then off, then wait about 1
second and turn on again. A different color option will appear. The LED light
will turn off automatically after 4 hours.
Preset Filter Cycles
There are two filter cycles per day. The first filter cycle begins 6 minutes after
the spa is powered up. The second filter cycle begins 12 hours after the start of
the first cycle. Most spa owners with basic control systems power up their spa
at approximately 6:00-7:00 a.m. so the morning and evening filtration cycles
are close to when the spa is most likely to be used (see “Economy Mode”
paragraph above). The filtration pump (either pump 1 or circ pump) and ozone
purifier* run during filtration cycles. In addition, all jet pumps will run for the
first 10 minutes of each filter cycle to purge the JetPaks™ and JetPods™. The
factory filter cycle duration is set for 2 hours twice per day for non-circ mod-
els, and 6 hours twice per day for circ pump models. Filter cycle duration can
be programmed by the spa owner for one hour up to 12 hours (F1-F12).
To change the filter cycle duration, press temp + jets 1. Press temp to cycle
through the 1 to 12 hour filter duration options (F1-F12). Press jets 1 to select
the desired filter duration. Press temp again to cycle through the options for
number of filter cycles per 24 hour period. The display will show three options:
“dn” (for day and night),” d” (day only), or “n” (night only). Press jets 1 to select
desired option. Press jets 1 again to exit the program.
Note:
For most applications, “dn” (day and night) filter cycles is recommended
as two 2-hour filter cycles 12 hours apart is better than one 4 hour filter cycle
once per day. For continuous filtration, use F12 and dn. Allowing the filter
pump to operate for extended periods of time with the cover on the spa will
result in a rise of the spa water temperature. During warmer months of the
year, it is advisable to set the duration of the filtration cycle to the minimum
level needed to keep the water clean.
Freeze Protection
If the temperature drops to 44°F (7°C) within the heater, the pump(s)
automatically activates to provide freeze protection. The pump will stay on 4
minutes after the sensor has detected the temperature has reached 45°F (7°C)
or higher.
Ozone Purifier
(optional)
The ozone purifier runs during filter cycles. The ozone is disabled during spa
use by either turning pump 1 to high speed or pump 2 to high or low speed
(for non-circ spas), or, for a circ pump spa, by turning either pump 1 or pump
2 to any speed.
Icon Legend
Heat Icon - Indicates different
stages of heating
Jets Icon - Spins fast on high
speed/spins slow on low speed
Light Icon