Chapter 7: BIOS
7-15
IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA,
ATAPI devices installed in the system. The options are 0 (sec), 5, 10, 15, 20,
25, 30, and 35.
PCI/PnP Configuration
Clear NVRAM
This feature clears the NVRAM during system boot. The options are
No
and
Yes.
Plug & Play OS
Selecting Yes allows the OS to configure Plug & Play devices. (This is not
required for system boot if your system has an OS that supports Plug & Play.)
Select
No
to allow the AMI BIOS to configure all devices in the system.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus.
Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32,
64
, 96, 128, 160, 192, 224 and 248.
PCI IDE BusMaster
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE
drives. The options are Disabled and
Enabled
.
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option
ROM
Select Enabled to enable the onboard LAN1 or LAN2 Option ROM. This is
to boot computer using a network interface. The options are Enabled and
Disabled
.
Super IO Device Configuration
Serial Port1 Address/ Serial Port2 Address
This option specifies the base I/O port address and the Interrupt Request address
of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from
accessing any system resources. When this option is set to Disabled, the serial
port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to
to use the S.M.A.R.T. to support hard drive disk. The options are Disabled,
Enabled, and
Auto
.
32Bit Data Transfer
Select Enable to enable the function of 32-bit IDE data transfer. The options are
Enabled
and Disabled.
Summary of Contents for R425-E2
Page 1: ...NOVASCALE R425 E2 Installation and User s Guide REFERENCE 86 A1 53FA 00...
Page 2: ......
Page 10: ...Notes viii NovaScale R425 E2 Installation and User s Guide...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 30: ...NovaScale R425 E2 Installation and User s Guide 3 4...
Page 74: ...5 40 NovaScale R425 E2 Installation and User s Guide...
Page 100: ...6 26 NovaScale R425 E2 Installation and User s Guide Notes...
Page 130: ...7 30 NovaScale R425 E2 Installation and User s Guide Notes...
Page 132: ...A 2 NovaScale R425 E2 Installation and User s Guide Notes...
Page 152: ...B 20 NovaScale R425 E2 Installation and User s Guide...
Page 154: ...C 2 NovaScale R425 E2 Installation and User s Guide Notes...
Page 155: ......
Page 156: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 53FA 00...