Pool/Spa Modes

 

The control is equipped with two independent thermostats, one for pool temperature and one for spa temperature.  
This is to allow the user to preset a temperature of their choice and switch between the two settings.  

 
To change between pool and spa modes, 

 

Press the SET button until the control reads P_S 

 

Press either arrow key to switch from POL to SPA 

 

Once the heating mode has been selected, it will be displayed for five seconds and then return to the actual 
pool water temperature. The lights on the right side of the display indicate the selected mode.  

 

ATTENTION!

  There is a 3 minute time delay upon initiation of a heating cycle.  This is to ensure that the critical 

components do not fail due to short cycling of the heater. 
 

Displaying the Temperature in °F or °C 

 

Heater comes pre-set in 

°F 

mode.  If desired in

 

°C 

mode, please call factory for instructions

 

 

Keypad Lockout Feature 

 

 

Locking 

 

 

To lock the keypad press the SELECT button for 5 seconds and the display will show spacing for a two digit 
code “_ _” at the right hand side. Press Up and Down buttons to enter the code starting from 00 to 99. Enter 
the code according to the pre-set. The control is shipped with pre-set code of 20, and then  press SELECT 
button. Each time a button is pressed the control will show “LOC” for 3 seconds and then show water 
temperature 

 

 

 

 

 

Unlocking 

 

To unlock the keypad press the SELECT button for 5 seconds and the display will show spacing for a two 
digit code “_ _” at the right hand side. Enter the code and press the SELECT button. If the correct code is 
entered then the control switches to show the water temperature. If the incorrect code is entered then the 
control will flash “LOC” for 3 seconds and switch back to “_ _”. If nothing is entered for the next 5 seconds 
then the control will switch to show water temperature and remain locked.  

  

 

 

Setting the Code 

 

With the power to the heater is off, press and hold the SELECT button while applying power. The control 
will then show the spacing for two digits “_ _”. Enter the desired code and press SELECT to save it. 

 

 

Summary of Contents for BR100 S7

Page 1: ...Pool Spa Heat Pump Installation Operation Manual Models BR80 XW BR115 XW BR135 XW BR100 S7 BR115 S7 BR135 S7 BR 40101 Version 2 0...

Page 2: ...ida is 50 fifty US dollars Claims for warranty reimbursement must have prior authorization by Built Right and be performed by a Factory Authorized Service Agent This warranty is void if the product is...

Page 3: ...Wiring Diagram 7 Heat Pump Operation Digital Control Operation 8 10 Control On Off 8 Pool Spa Mode 9 Displaying the Temp in F or C 9 Keypad Lockout Feature 9 Changing Set Point Temperature 10 Heater...

Page 4: ...________________________________________ Dealer Name _____________________________________________________________________ Dealer Address ______________________________________________________________...

Page 5: ...mp is best utilized for maintaining a set water temperature It s not intended to provide fast heating When not in use for long periods of time it is acceptable to shut off your heat pump When you have...

Page 6: ...values are different from those specified use the greater value to ensure safe and proper installation Equipment Pad Install the heat pump on a flat slightly pitched surface preferably a concrete or f...

Page 7: ...r level isolation valves must be installed The pool heater should not be installed more than 6 feet below the pool water surface or no more than 15 feet above the pool level Be advised that when pool...

Page 8: ...s of a pool structure including reinforcing steel metal fittings and above ground equipment be bonded together with a solid copper conductor not smaller than 8 AWG The heat pump along with pumps and o...

Page 9: ...0 Black Orange 230V Red Wire Use for 208 V Application Legend Comp Compressor CC Compressor Capacitor EVAP Defrost Temp Sensor FC Fan Capacitor FM Fan Motor HPS High Pressure Switch LPS Low Pressure S...

Page 10: ...urn heater on Press the set button until the word Off appears Press down button until No appears Heater is now on Pool Spa lights will illuminate beside display indicating heater is on Use the up or d...

Page 11: ...ess the SELECT button for 5 seconds and the display will show spacing for a two digit code _ _ at the right hand side Press Up and Down buttons to enter the code starting from 00 to 99 Enter the code...

Page 12: ...the pump is activated You will then need to set the water temperature to your desired set point The heater will start after a three minute time delay if the desired set point is higher than the actua...

Page 13: ...sive simply rinse the evaporator coil with fresh water Use of a garden hose with low water pressure will work best Use extra care so that you don t bend the coil fins The heater s housing is made from...

Page 14: ...basket pump strainer basket and pool filter are all clean Ensure valves are set properly Control Display is flashing FS Or FS1 FS2 FS3 FS4 Air temperature is too cold for heater operation Wait until...

Page 15: ...ill assure you of in warranty service Notes ________________________________________________________________________________ ___________________________________________________________________________...

Page 16: ...Built Right Pool Heaters LLC 8260 Pascal Dr Punta Gorda Fl 33950 4726 www BuiltRightPoolHeaters com...

Reviews: