background image

Page | 6 

ELECTRICAL HOOK UP 

 

The wiring of your heater should be performed by a qualified electrician in accordance 
with local code requirements

.  

 

 

CAUTION!

  

The main power disconnect must be off before opening the access panel.

   

 

IMPORTANT!

  

The electrical conduit 

must

 be run up through the base of the unit and 

connected at the control box with a conduit connector. 
 

Check the heat pump data label for required breaker size. 

Copper wire and a properly sized breaker must be used

 

WARNING!

  

The unit must always be powered off before opening the access panel. 

 

BONDING 

The National Electrical Code and most other codes require that all metallic components of a pool 
structure, including reinforcing steel, metal fittings, and above ground equipment be bonded 
together with a solid copper conductor not smaller than 8 AWG.  The heat pump, along with 
pumps and other pool equipment must be connected to this bonding grid. To ensure this 
requirement is met, a bonding lug is provided on the front bottom right below the control access 
panel (see drawing below).  ALL metal and electrical components of the pool system must be 
bonded together.

 

 On many older pools, the bonding wire may not exist.  In this case, a 6 to 8 ft. 

copper rod must be driven into the ground near the pool equipment and all electrical and metal 
components must be bonded to the rod.   

Warranty will be void if system is not properly bonded

!

 

 

Control
  Box

Approved Connector

To Main Power

Flexible Conduit

Attach Bond Wire From
Pool Pump Here

 

Summary of Contents for BR100 S7

Page 1: ...Pool Spa Heat Pump Installation Operation Manual Models BR80 XW BR115 XW BR135 XW BR100 S7 BR115 S7 BR135 S7 BR 40101 Version 2 0...

Page 2: ...ida is 50 fifty US dollars Claims for warranty reimbursement must have prior authorization by Built Right and be performed by a Factory Authorized Service Agent This warranty is void if the product is...

Page 3: ...Wiring Diagram 7 Heat Pump Operation Digital Control Operation 8 10 Control On Off 8 Pool Spa Mode 9 Displaying the Temp in F or C 9 Keypad Lockout Feature 9 Changing Set Point Temperature 10 Heater...

Page 4: ...________________________________________ Dealer Name _____________________________________________________________________ Dealer Address ______________________________________________________________...

Page 5: ...mp is best utilized for maintaining a set water temperature It s not intended to provide fast heating When not in use for long periods of time it is acceptable to shut off your heat pump When you have...

Page 6: ...values are different from those specified use the greater value to ensure safe and proper installation Equipment Pad Install the heat pump on a flat slightly pitched surface preferably a concrete or f...

Page 7: ...r level isolation valves must be installed The pool heater should not be installed more than 6 feet below the pool water surface or no more than 15 feet above the pool level Be advised that when pool...

Page 8: ...s of a pool structure including reinforcing steel metal fittings and above ground equipment be bonded together with a solid copper conductor not smaller than 8 AWG The heat pump along with pumps and o...

Page 9: ...0 Black Orange 230V Red Wire Use for 208 V Application Legend Comp Compressor CC Compressor Capacitor EVAP Defrost Temp Sensor FC Fan Capacitor FM Fan Motor HPS High Pressure Switch LPS Low Pressure S...

Page 10: ...urn heater on Press the set button until the word Off appears Press down button until No appears Heater is now on Pool Spa lights will illuminate beside display indicating heater is on Use the up or d...

Page 11: ...ess the SELECT button for 5 seconds and the display will show spacing for a two digit code _ _ at the right hand side Press Up and Down buttons to enter the code starting from 00 to 99 Enter the code...

Page 12: ...the pump is activated You will then need to set the water temperature to your desired set point The heater will start after a three minute time delay if the desired set point is higher than the actua...

Page 13: ...sive simply rinse the evaporator coil with fresh water Use of a garden hose with low water pressure will work best Use extra care so that you don t bend the coil fins The heater s housing is made from...

Page 14: ...basket pump strainer basket and pool filter are all clean Ensure valves are set properly Control Display is flashing FS Or FS1 FS2 FS3 FS4 Air temperature is too cold for heater operation Wait until...

Page 15: ...ill assure you of in warranty service Notes ________________________________________________________________________________ ___________________________________________________________________________...

Page 16: ...Built Right Pool Heaters LLC 8260 Pascal Dr Punta Gorda Fl 33950 4726 www BuiltRightPoolHeaters com...

Reviews: