Revision 0.1 [05/10/18]
Page 7
Installation
Procedure
Unit Installation & Ducting
1.
Review Ducting section below to determine most applicable ducting scheme.
2.
It is recommended to install the CERV2 in a plastic appliance basin if location is such that water
damage is a concern. A clogged condensate line can cause water to pool around the CERV2. A
moisture sensor and alarm can also be used to notify occupants of a problem.
3.
Fix the CERV into position and ensure stability.
Unit must be level
. Vibration feet (not provided)
should be placed under CERV to reduce vibration and to keep CERV off of a potentially wet floor
surface.