7
P2 Waiting time until reduction
The temperature controller switches automatically to operation with value reduction, if the hot melt applicator is not in use for the time
adjusted here.
P19 Button locking
Button locking allows the blocking of operating buttons. When locked,alteration of factory adjustment by buttons is impossible. When
trying to do so, the report “—-“ will be shown in the display.
3.4.3 Status reports and malfunction display
4. Operation
4.1 Filling
Only open the applicator when it is heated!
Protection against damage to the cover seal
Risk of burns on hot metal parts.
Place the applicator in the supply unit.
Heat up the applicator.
Hold the applicator by the handle (16) with one hand.
Turn the lever (10) with the other hand clockwise and open the closure cap (11).
Do not overfill the melt tank (max. level = 1 inch below top).
Hot melt adhesives expand with increasing temperature.
Place hot melt adhesive into the melt tank.
Close the closure cap (11).
4.2 Applying and metering hot melt adhesive
Ensure that there is always sufficient hot melt adhesive in the melt tank to avoid ”running empty“.
Heat up the applicator for approx. 5 minutes.
Pull the trigger (15).
You can meter the application quantity by changing the pressure (up to 87 psi / 6 bar) and/or selecting an appropriate nozzle size.
As soon as you release the trigger (15) the compressed air supply is stopped and the melt tank is vented.
4.3 Setting the spray (PowerLine Spray)
The spray pattern can be altered by adjusting the pressure regulator (5).
Establish the optimum application spray by adjusting the spray air choke (14) in the protection cap (13).
Adjusting clockwise decreases spray air pressure, adjusting counterclockwise increases spray air pressure.
Reading
Reason
Action
Decimal point left flashes
Heating activated
heating will be finished, if the scheldued value is reached
within less than 2 degree
Decimal point right lights
up
Scheduled value reduction
activated
see parameter P1 and P2
ERR
Exceeding the temperature noted in
parameter P31
let cool down
F1L
Sensor failure, short cicuit
Check sensor
Falt indication will be shown even after remedy of fault until
it is acknoledged with the Down button
F1H
Sensor failure, sensor break
Check sensor
Falt indication will be shown even after remedy of fault until
it is acknoledged with the Down button
--
Button locking activated
see parameter P19
EP
Loss of data in the parameter
memory
Repair of the temperature controller
2SHUDWLRQVHWWLQJV2SHUDWLRQ