background image

4

1. Specifications

Description

PowerLine Extrusion

PowerLine Spray

Part no.

H206600

H206700

Scope of supply

Applicator, tool set, working bracket/workstation (optional)

Weight of applicator

approx. 3.09 lbs 1.40 kg

approx. 3.74 lbs / 1.70 kg

Power requirements

120 V AC / 60 Hz

Power input

600 watts

Current input

5 A

Degree of protection
(acc. to DIN IEC 34 T5)

IP 30

Protection class
(acc. to DIN VDE 0720)

I

(safety earth terminal)

Heat control

electronic

Heat limitation

Safety temperature controller (500 °F / 260 °C ± 11 °C) limiting thermostat

Operating temperature

100 °F to 410 °F / 40 - 210 °C (variable adjustment)

Temperature tolerance

± 2 °F

Factory adjustment

350 °F / 180 °C

Temperature indication

Digital by LED display

Automatic temperature reduction sys-
tem (ACE)

The temperature is reduced

by 100 °F / 40 °C after operation break of 30 minutes

Heat up time

Approx. 3 - 4 min.

Melting capacity
(according to hot melt type)

For plugs: 7.5 lbs/h / 3.2 kg/h

For granulate: 2.87 lbs/h / 1.3 kg/h

Capacity melt tank

200 ml

Feed system

Compressed air

Compressed air supply

145 psi / 10 bar max. (maintenance unit with quick-action connector)

Operating pressure

15 to 87 psi / 1.5 to 6 bar

Protection against excess
pressure

Pressure limitation (reaction pressure) 87.2 psi / 6 bar)

Air consumption (at 87 psi operating 
pressure)

1 l per trigger

max. 1 l per second

Nozzles (Standard)

Conical nozzle

dia 1.5 mm

Spiral nozzle

dia 1.5 mm

Length of supply line
with electric and pneumatic
connection

9.84 ft / 3.0 m

Recommended hot melt adhesive

BÜHNEN-Hot melt adhesives in plugs or granulate

6SHFLILFDWLRQV

Summary of Contents for PAM Powerline H206700

Page 1: ...ing into service Keep them for future use Adherence to these operating and safety instructions and all statutory regulations is the responsibility of the operator 2SHUDWLQJ QVWUXFWLRQV IRU RW 0HOW SSOLFDWRU 3 0 3RZHUOLQH WUXVLRQ 3 0 3RZHUOLQH 6SUD ...

Page 2: ...the second operatig level 3 4 3 Status report and malfunction display 4 Operation 7 4 1 Filling 7 4 2 Applying and metering hot melt adhesive 8 4 3 Setting the spray PowerLine Spray 8 4 4 Automatic temperature reduction system ACE 8 4 5 Interruption of work End of shift 8 4 6 Troubleshooting and remedying faults 8 5 Maintenance Servicing 8 5 1 Maintenance intervals 9 5 2 Cleaning 9 5 2 1 Cleaning ...

Page 3: ...1 Closure cap 3 Pressure gauge 12 Suspension point 4 Pressure regulator 13 Protection cap 5 Digital display 14 Spray air choke 6 Start Stop button 15 Protection cap 7 Set button 16 Trigger 8 Down button 17 Handle 9 Up button 18 Stand hoop UUDQJHPHQW 3RZHU LQH 6SUD 3RZHU LQH WUXVLRQ SSOLFDWRU ...

Page 4: ...n Digital by LED display Automatic temperature reduction sys tem ACE The temperature is reduced by 100 F 40 C after operation break of 30 minutes Heat up time Approx 3 4 min Melting capacity according to hot melt type For plugs 7 5 lbs h 3 2 kg h For granulate 2 87 lbs h 1 3 kg h Capacity melt tank 200 ml Feed system Compressed air Compressed air supply 145 psi 10 bar max maintenance unit with qui...

Page 5: ...or combustible gases Irritation of the mucous membranes by vapours emitted by hot melt adhesive 2 3 Instructions on safe operation The applicator may only be used with the nozzle pointing dowwards Do not overfill the melt tank max level 1 inch below top If the heated applicator is tilted and or the tank is overfilled the hot melt adhesive can enter the ventilation pipe This may cause mal functions...

Page 6: ...owing on the digital display 5 to the level recommended by the adhesive manufacturer Switching off even for a long period does not change the temperature set Environmental conditions as influence of strong high fre quency interference transmitter stations and electrical fluctuations may cause differences of 2 4 F It is therefore recommended that the preselected temperature is checked occasionally ...

Page 7: ...5 minutes Pull the trigger 15 You can meter the application quantity by changing the pressure up to 87 psi 6 bar and or selecting an appropriate nozzle size As soon as you release the trigger 15 the compressed air supply is stopped and the melt tank is vented 4 3 Setting the spray PowerLine Spray The spray pattern can be altered by adjusting the pressure regulator 5 Establish the optimum applicati...

Page 8: ...ty equipment heat protection gloves protective goggles increases safety Before servicing or performing maintenance work on components which come into contact with hot melt adhesive they must be heated up beforehand heat up the applicator or use an external hot air gun Fault Possible cause Remedy see Section Nozzle leaks Nozzle valve damaged PowerLine Extrusion Clean or change nozzle foot PowerLine...

Page 9: ... 5 3 4 5 3 Nozzle systems 5 3 1 Changing the conical nozzle PowerLine Extrusion only heated up Fig 1 Tools required 2 size 19 open ended spanner 1 spring ring pliers Remove the cartridge Remove the circlip A1 Remove the nozzle kit part A2 to A7 out of the applicator Prevent the nozzle foot A3 from moving and unscrew the conical nozzle A2 Screw the new nozzle A2 on hand tight and allow the nozzle t...

Page 10: ...0 C the tool should be thoroughly heated Turn off the compressed air supply Loosen the Allen screw A5 in the protection cap A4 for half a turn Turn the valve seat A6 by means of the open ended spanner to the desired direction Tighten the Allen screw A5 again 5 3 4 Changing the spiral nozzle compression spring and ball PowerLine Spray Fig 2 Tools required 1 hook wrench 1 size 11 open ended spanner ...

Page 11: ... in open position when inserted Tighten screws 1 of locking device 2 after adjustment If the leak cannot be rectified change the cover seal 9 5 5 Changing the cover seal If the change of cover pressure will not solve the leak the cover seal has to be changed Tools required 1 small screw driver Remove the cover gasket 9 by means of the screw driver Renew the cover gasket 9 6 Repairs Repair work may...

Page 12: ...PAM Fastening Technology Inc Division of BÜHNEN Charlotte N C USA Telefon 704 394 31 41 Telefax 704 394 93 39 www pamfast com sales pamfast com ...

Reviews: