Starting
22
3.4.2
Reading out and setting the control parameters
Pressing the Up and Down buttons simultaneously for at least 4 s brings up a parameter
list. Some parameters can be set, others only read out. The table below summarises the
parameters:
Vorebene:
Para-
meter
Description
Setting range
Factory
setting
b01
Behaviour after power-on
0: Off
1: On
2: Auto
0
b14
Lock target value,
the adjustment of the working temperature can be
locked here.
0: not locked
1: locked
0
C02
Target value lowering after time C03
- 180 K...0 K
40 K
C03
Waiting time until lowering (reset with button)
1...999 min
30 min
C09
Delay after heating phase has ended (heating LED bar
then lights up continuously)
1...99 min
2 min
P07
Set air pressure
P05...P06
Expanded menu –
Parameter levels
5,0 bar
oPL/H
Operating time display (without standby „OFF“)
1/1000 hours
0/0
PuL/H
Number of triggers displayed during operating time
1/1000
trigger
0/0
Str
Acknowledgement Service
0 -> 1 -> 0
0
PA
Access to the expanded menu
Password
expanded menu –
level L
1
You can browse upwards through the parameter list with the Up button and downwards
with the Down button. Press the “Set” button to display the value assigned to a parameter.
You can adjust the value assigned to a settable parameter by additionally pressing the Up/
Down buttons.
3.4.3
Setting the air pressure
If too much or too little adhesive is discharged, you can change the amount by adjusting
the air pressure. More air pressure also means more adhesive and vice versa. In order to
use the level indicator, you must change parameter P07 accordingly, see Section 3.4.2.