TC-MIDI (+)
1.4 Ordering instructions
1.4.1 Gas cooler models with one gas path inside the heat exchanger
The item number is a code for the configuration of your unit. Please use the following model code:
4496
3
1
1
X 0 X
1
X X X X X X X 0 X 0 Product Characteristics
Gas cooler types
1
TC-MIDI 6111: Ambient temperature 40 °C
2
TC-MIDI 6112: Ambient temperature 60 °C
Certifications
0
Standard applications – CE
Supply voltage
1
115 V AC, 50/60 Hz
2
230 V AC, 50/60 Hz
Heat exchanger
1
1
0
Stainless steel, TS, metric
1
1
5
Stainless steel, TS-I, US
1
2 0
Duran glass, TG, metric
1
2
5
Duran glass, TG-I, US
1
3 0
PVDF, TV-SS, metric
1
3
5
PVDF, TV-SS-I, US
Condensate drain
2)
0
without condensate drain
1
CPsingle with hose nipple, angled
3
CPsingle with screw connection
4)
Sample gas pumps
1)
0
without sample gas pump
1
P1, PVDF, bottom mounted
2
P1, with bypass valve, bottom mounted
6
P1, PVDF, mounted externally
7
P1, with bypass valve, mounted externally
Moisture detector
2)
/ filter
0 0
without filter, without moisture detector
0
1
without filter, 1 moisture detector with PVDF adapter
3)
1
0
1 filter, without moisture detector
1
1
1 filter with built-in moisture detector
Signal outputs
0 0
status output only
1
0
Analog output, 4..20 mA, incl. status output
2 0
Modbus RTU digital output, incl. status output
Delta T control
0 0 without Delta T control
1
0 Delta T control option
1)
Factory installed tubing for suction operation.
2)
With this option, the maximum ambient temperature is limited to 50 °C.
3)
Also available in stainless steel.
4)
Metric or US connection, per heat exchanger.