TC-MIDI (+)
Description
FC
Address
Access Data type
Default
Min
Max
Selection
Resolution Unit
De-/activate condensate pump(s)
3, 16
9008
R/W
Uint16
3
-
-
3:= Pump active
4:= Pump inactive
-
-
Modbus Baudrate selection
3, 16
9009
R/W
Uint16
3
-
-
1 := 4800
2 := 9600
3 := 19200
4 := 38400
5 := 57600
6 := 115200
-
-
Modbus Parity selection
3, 16
9010
R/W
Uint16
2
-
-
0 := None
1 := Odd
2 := Even
-
-
Modbus Device address selection
3, 16
9011
R/W
Uint16
10
1
247
-
1
-
Lock menu
3, 16
9012
R/W
Uint16
0
0
9999
-
1
-
TEST
3
9990
R
Uint32
12648430
-
-
-
1
-
TEST_UINT16
3, 16
9992
R/W
Uint16
206
0
65535
-
1
-
TEST_INT16
3, 16
9993
R/W
Int16
-206
-32768
32767
-
1
-
TEST_UINT32
3, 16
9994
R/W
Uint32
2766
0
4294967295 -
1
-
TEST_INT32
3, 16
9996
R/W
Int32
-2766
0x80000000 0x7fffffff
-
1
-
TEST_Float
3, 16
9998
R/W
Float
-10.5
-
-
-
Status register overview
3
10000
R
Uint16
0
Bit 0 := Status information register 10001
Bit n := Status information register 10000 + n + 1
-
-
Condition code register 1
3
10001
R
Uint16
0
-
-
Bit 0 := Device status
Bit 1 := Device in error status
Bit 2 := Target temperature range overrun
Bit 3 := Target temperature range underrun
Bit 4 :=
Bit 5 :=
Bit 6 := Moisture detector 1 connected
Bit 7 := Moisture detector 2 connected
-
-
Condition code register 2
3
10002
R
Uint16
0
-
-
Bit 0 :=
Bit 1 :=
Bit 2 := Initialization phase
Bit 3 :=
Bit 4 :=
Bit 5 :=
Bit 6 := FF1 moisture alarm
Bit 7 := FF2 moisture alarm
-
-
28
Bühler Technologies GmbH
BE440016 ◦ 07/2022
Summary of Contents for ModbusRTU TC-MIDI
Page 53: ......