background image

1

 

Key to symbols and safety instructions

Logano GB102 – 6 720 811 066 (2014/09)

3

1

KEY TO SYMBOLS AND SAFETY INSTRUCTIONS

1.1

Key to symbols

Warnings

The following keywords are defined and can be used in this document:

NOTICE

 indicates a situation that could result in damage to property 

or equipment.

CAUTION

 indicates a situation that could result in minor to medium 

injury.

WARNING

 indicates a situation that could result in severe injury or 

death.

Important information

Additional symbols

1.2

Safety precautions

If you smell gas

A gas leak could potentially cause an explosion. If you smell gas, observe 
the following rules.

▶ Prevent flames or sparks:

– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any equipment.
– Do not use the telephone or ring doorbells.

▶ Turn off the gas at the meter or regulator.
▶ Open windows and doors.
▶ Warn your neighbours and leave the building.
▶ Prevent anyone from entering the building. 
▶ Well away from the building: call the Emergency services
▶ L.P.G. boilers: Call the supplier’s number on the side of the gas tank.

BOILER OPERATION:
This boiler must only be operated by a responsible adult who has 
been instructed in, understands, and is aware of the boiler's 
operating conditions and effects.

HEALTH AND SAFETY

The appliance contains no asbestos and no substances have been used 
in the construction process that contravene the COSHH Regulations 
(Control of Substances Hazardous to Health Regulations 1988).

COMBUSTION AND CORROSIVE MATERIALS

Do not store or use any combustible materials (paper, thinners, paints 
etc.) inside or within the vicinity of the appliance.

Chemically aggressive substances can corrode the appliance and 
invalidate any guarantee.

FITTING AND MODIFICATIONS

Fitting the appliance and any controls to the appliance may only be 
carried out by a competent engineer in accordance with the current Gas 
Safety (Installation and Use) Regulations.

Flue systems must not be modified in any way other than as described in 
the fitting instructions. Any misuse or unauthorised modifications to the 
appliance, flue or associated components and systems could invalidate 
the guarantee. The manufacturer accepts no liability arising from any 
such actions, excluding statutory rights.

SERVICING

Advise the user to have the system serviced annually by a competent, 
qualified Gas Safe registered engineer. Approved spares must be used 
to help maintain the economy, safety and reliability of the appliance.

IMPORTANT

 

The service engineer must complete the Service Record on the 
Benchmark Checklist after each service.

2

PRODUCT INFORMATION

2.1

Intended use

The appliance is only for use in sealed hot water Heating systems are 
installed according to you countries local regulations. Any other use is 
improper. Any damage resulting from an improper installation are 
excluded from liability. The commercial and industrial use of the 
equipment for the generation process heat is excluded. Advice for 
permissible operating conditions are listed in the Installation, 
Commissioning and Servicing instructions for the installer.

2.2

EC declaration of type conformity

This product is in design and operation of the European Directives and 
the supplementary national requirements. 

Conformity has been demonstrated by the CE marking. 

To request the declaration of conformity of the product, see the contact 
details on the back of this manual 

The appliance meets the requirements for gas condensing boilers in 
terms of energy saving regulations. 

The unit is tested according to EN 677

2.3

Overview of boiler types

The 

system

 gas fired condensing boiler has an integrated circulation 

pump and optional built in diverter valve to direct the heating to the 
radiators or to connect to an indirectly heated hot water cylinder. 

The system boiler is incorporated into a sealed pressurized system 
which is maintained by an expansion vessel.

The 

Regular

 gas fired condensing boiler is for use in an open vented 

system with an indirectly heated hot water cylinder. 

The regular boiler is used in an unpressurized system which is 
maintained by a header tank.

The heating system has externally mounted circulation pump and a three 
way valve for controlling the heating or hot water.

Warnings in this document are identified by a warning 
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and 
seriousness of the ensuing risk if measures to prevent 
the risk are not taken.

This symbol indicates important information where 
there is no risk to people or property.

Symbol

Explanation

Step in an action sequence

 

Cross-reference to another part of the document

List entry

List entry (second level)

Table 1  

Summary of Contents for Logano plus GB102

Page 1: ...Vor Installation und Wartung sorgfältig lesen User Instructions Gas fired condensing boiler Logano plus GB102 GB102S System boiler16 30 Regular boiler 16 30 42 6 720 811 066 2014 03 ...

Page 2: ...ient offering you economical running costs and value for money It sits in SEDBUK 2005 Band A and is therefore amongst the top energy rated boilers available There is also the reassurance of our no nonsense 2 years parts and labour guarantee backed up by Worcester Total Cover an optional complete maintenance scheme to keep your boiler operating at peak condition and efficiency Table of Contents 1 K...

Page 3: ...SERVICING Advise the user to have the system serviced annually by a competent qualified Gas Safe registered engineer Approved spares must be used to help maintain the economy safety and reliability of the appliance IMPORTANT The service engineer must complete the Service Record on the Benchmark Checklist after each service 2 PRODUCT INFORMATION 2 1 Intended use The appliance is only for use in sea...

Page 4: ... compensation External sensor required 5 Chimney sweep mode 6 Fault alert 7 Service mode 6 7 Maintenance mode 8 Burner on 9 Temperature units C 10 Confirmation 11 Scroll up or down through the sub menus 12 Alphanumeric display e g Temperature 13 Text display 14 Heating mode off 15 Heating mode on 3 3 Appliance on off switch Initial switch on Switch on at the with the main appliance switch The disp...

Page 5: ...the button The display shows the flashing maximum flow temperature and the Heating mode symbol is displayed Fig 6 Maximum flow temperature Press the or button to set the desired maximum flow temperature Press ok to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 7 Setting the maximum flow temperature The controller has a pump anti seize function...

Page 6: ...t temperature The control then switches back into heating mode 3 5 2 Setting the DHW temperature DHW or Eco mode page 6 Press the button The set DHW temperature flashes Fig 10 Pressthe or button toselectthedesiredDHWtemperature set between 40 and 60 C Press the ok button to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 11 3 6 Control unit sett...

Page 7: ...rol system manual Cylinder frost protection Even when the DHW mode is switched off the cylinder is protected against frost damage Set the DHW mode to off Section 3 5 1 4 SYSTEM OPERATING PRESSURE 4 1 Check the water pressure System boiler only The normal operating pressure is between 1 and 2 bar If the pressure needs to be constantly re pressurized or the pressure is constantly over the 2 5bar mar...

Page 8: ... for relatively long periods of time but will use less gas than a boiler that continually switches on and off CENTRAL HEATING SYSTEMS WITH ROOM THERMOSTAT THERMOSTATIC RADIATOR VALVES With modern heating systems set around a 20 C heat loss the optimum setting for a condensing boiler will be approximately between the first and second segment on the central heating temperature control The system mus...

Page 9: ... ok button to save the setting The tick symbol is displayed briefly to confirm the setting Setting the optional control system See operating instructions for the control systems Setting the maximum flow temperature Press the button Press the or button the set the flow temperature Setting the DHW temperature Press the button Press the or button to set the DHW temperature Press the ok button to save...

Page 10: ...8 Logano GB102 6 720 811 066 2014 09 10 Notes ...

Page 11: ...8 Logano GB102 6 720 811 066 2014 09 11 Notes ...

Page 12: ......

Reviews: