1
Key to symbols and safety instructions
Logano G315 – 6 720 817 939 (2017/02)
3
8
Connecting the boiler on the flue gas side . . . . . . . . . . . . . . . 24
8.1
Installing a vent pipe sealing collar (accessory) . . . . . . 24
8.1.1
Installing a flue gas temperature sensor (accessory) . . 24
9
Installing a control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9.1
Installing the Logamatic control panel . . . . . . . . . . . . . 25
9.2
Installing temperature sensor assembly . . . . . . . . . . . . 25
9.3
Installing the Hydrolevel Hydrostat Control and
Hydrolevel Electro Well . . . . . . . . . . . . . . . . . . . . . . . . . 26
9.4
Wiring Hydrolevel Hydrostat with Riello F15 Burner . . 27
9.5
Wiring Hydrolevel Hydrostat with Beckett
CF500 & CF800 Burner . . . . . . . . . . . . . . . . . . . . . . . . 29
10 Mounting the burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11 System start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
11.1
Filling the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
11.2
Commissioning the system . . . . . . . . . . . . . . . . . . . . . . 31
11.3
Start up the control panel . . . . . . . . . . . . . . . . . . . . . . . 31
11.4
Initial burner start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
11.5
Raising flue gas temperature . . . . . . . . . . . . . . . . . . . . . 31
11.6
Commissioning log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
12 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
12.1
Shutting down the heating system via the control
panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
12.2
Shutting down the system in an emergency . . . . . . . . . 33
13 System inspection and maintenance . . . . . . . . . . . . . . . . . . . 33
13.1
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
13.2
Why is regular maintenance important? . . . . . . . . . . . . 33
13.3
Cleaning the boiler with cleaning brushes . . . . . . . . . . 33
13.4
Wet-cleaning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . 35
13.5
Checking the operating pressure . . . . . . . . . . . . . . . . . 35
13.6
Refilling with boiler water and purging the system . . . 35
13.7
Inspection and maintenance reports . . . . . . . . . . . . . . 36
14 Troubleshooting burner faults . . . . . . . . . . . . . . . . . . . . . . . . . 38
15 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
1
Key to symbols and safety instructions
1.1
Key to symbols
Warnings
The following keywords are defined and can be used in this document:
•
DANGER
indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
•
WARNING
indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
•
CAUTION
indicates a hazardous situation which, if not avoided,
could result in minor to moderate injury.
Important information
Additional symbols
Warnings in this document are identified by a warning
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and
seriousness of the ensuing risk if measures to prevent
the risk are not taken.
NOTICE:
Contains no warning triangle and indicates a
situation that could result in damage to property or
equipment, but no personal injury.
This symbol indicates important information where
there is no risk to people or property.
Symbol
Explanation
▶
Step in an action sequence
Cross-reference to another part of the document
•
List entry
–
List entry (second level)
Table 1
Summary of Contents for Logano G315
Page 55: ...Appendix Logano G315 6 720 817 939 2017 02 55 ...
Page 56: ......