Troubleshooting
3
Subject to modifications resulting from technical improvements!
Buderus Ltd. • http://www.buderus-domestic.co.uk
Servicing manual for wall-mounted condensing gas boiler 600 Series 11S/19S/24S/24C • Issued 02/2006
41
Fig. 38
Fault warning message 9U: Incorrect cable connection at UBA (KIM defective)
Flashing
Wiring to gas-valve assembly incorrect,
or loose wiring connections in UBA
U
9
Connections OK?
No
Fit the casing
"reset"
600 Series
11S / 19S / 24S / 24C
OK
A
Remove the casing (page 48)
KIM connected
correctly?
Check wiring connection in UBA
Set the mains switch to "0".
Use the corresponding flow diagram
to diagnose and deal with the
fault
Contact Buderus
Customer Service
Fit the casing
No
No
Yes
Set the mains switch to "1".
"reset"
"reset"
Set the mains switch to "1".
Yes
Yes
No
Connect all terminals correctly
Yes
New fault warning
message
9U?
Other fault warning
message ?