Buchi HydrolEx H-506 Operation Manual Download Page 30

Quality in your hands

BUCHI Affiliates:

We are represented by more than 100 distribution partners worldwide.  
Find your local representative at: www.buchi.com

BUCHI Support Centers:

Europe

Switzerland/Austria

BÜCHI Labortechnik AG

CH – 9230 Flawil 
T +41 71 394 63 63
F +41 71 394 64 64
[email protected]
www.buchi.com

Benelux

BÜCHI Labortechnik GmbH

Branch Office Benelux 
NL – 3342 GT Hendrik-Ido-Ambacht 
T +31 78 684 94 29
F +31 78 684 94 30 
[email protected]
www.buchi.com/bx-en

France

BUCHI Sarl

FR – 94656 Rungis Cedex
T +33 1 56 70 62 50
F +33 1 46 86 00 31
[email protected]
www.buchi.com/fr-fr

Germany

BÜCHI Labortechnik GmbH

DE – 45127 Essen
T +800 414 0 414 0 (Toll Free)
T +49 201 747 49 0
F +49 201 747 49 20 
[email protected]
www.buchi.com/de-de

Italy

BUCHI Italia s.r.l.

IT – 20010 Cornaredo (MI)
T +39 02 824 50 11
F +39 02 575 12 855
[email protected]
www.buchi.com/it-it

Russia

BUCHI Russia/CIS

Russia 127287 Moscow
T +7 495 36 36 495
[email protected]
www.buchi.com/ru-ru 

United Kingdom

BUCHI UK Ltd.

GB – Oldham OL9 9QL
T +44 161 633 1000
F +44 161 633 1007
[email protected]
www.buchi.com/gb-en

Germany

BÜCHI NIR-Online

DE – 69190 Walldorf 
T +49 6227 73 26 60
F +49 6227 73 26 70
[email protected]
www.nir-online.de

China

BUCHI China

CN – 200233 Shanghai
T +86 21 6280 3366
F +86 21 5230 8821
[email protected]
www.buchi.com/cn-zh

India

BUCHI India Private Ltd.

IN – Mumbai 400 055 
T +91 22 667 75400
F +91 22 667 18986
[email protected] 
www.buchi.com/in-en

Indonesia

PT. BUCHI Indonesia

ID – Tangerang 15321
T +62 21 537 62 16
F +62 21 537 62 17
[email protected]
www.buchi.com/id-in

Japan

Nihon BUCHI K.K.  

JP – Tokyo 110-0008 
T +81 3 3821 4777
F +81 3 3821 4555
[email protected]
www.buchi.com/jp-ja

Korea

BUCHI Korea Inc.

KR – Seoul 153-782
T +82 2 6718 7500
F +82 2 6718 7599
[email protected]
www.buchi.com/kr-ko

Malaysia

BUCHI Malaysia Sdn. Bhd. 

MY – 47301 Petaling Jaya, 
Selangor 
T +60 3 7832 0310
F +60 3 7832 0309
[email protected]
www.buchi.com/my-en

Singapore

BUCHI Singapore Pte. Ltd. 

SG – Singapore 609919
T +65 6565 1175
F +65 6566 7047
[email protected]
www.buchi.com/sg-en

Thailand

BUCHI (Thailand) Ltd. 

TH – Bangkok 10600
T +66 2 862 08 51
F +66 2 862 08 54
[email protected]
www.buchi.com/th-th

Asia

America

Brazil

BUCHI Brasil Ltda.

BR – Valinhos SP 13271-200
T +55 19 3849 1201 
F +55 19 3849 2907
[email protected]
www.buchi.com/br-pt

USA/Canada

BUCHI Corporation

US – New Castle,  DE  19720
T +1 877 692 8244 (Toll Free)
T +1 302 652 3000
F +1 302 652 8777
[email protected]
www.buchi.com/us-en

South East Asia

BUCHI (Thailand) Ltd.

TH-Bangkok 10600
T +66 2 862 08 51
F +66 2 862 08 54
[email protected]
www.buchi.com/th-th

Middle East

BÜCHI Labortechnik AG

UAE – Dubai 
T +971 4 313 2860
F +971 4 313 2861
[email protected]
www.buchi.com

Latin America

BUCHI Latinoamérica  

S. de R.L. de C.V.

MX – Mexico City
T +52 55 9001 5386 
[email protected]
www.buchi.com/es-es

Summary of Contents for HydrolEx H-506

Page 1: ...HydrolEx H 506 Operation Manual 11593968 B en...

Page 2: ...ht to make changes to the manual as deemed necessary in the light of experi ence especially with respect to structure illustrations and technical details This manual is copyrighted Information from it...

Page 3: ...1 Principle of hydrolysis 10 3 2 Configuration 11 3 2 1 Front view 11 3 2 2 Rear view 12 3 3 Type plate 12 3 4 Scope of delivery 12 3 5 Technical data 12 3 5 1 HydrolEx H 506 12 3 5 2 Ambient conditio...

Page 4: ...Regular maintenance work 23 8 Help with faults 25 8 1 Troubleshooting 25 9 Taking out of service and disposal 27 9 1 Disposal 27 9 2 Taking out of service 27 9 3 Returning the instrument 27 10 Appendi...

Page 5: ...ere are four danger levels each identifiable by the signal word used Signal word Meaning DANGER Indicates a danger with a high level of risk which could result in death or serious injury if not preven...

Page 6: ...this Dialog Dialogs are marked up like this Button Buttons are marked up like this Field names Field names are marked up like this Menu Menu item Menus or menu items are marked up like this Status Sta...

Page 7: ...ied laboratory staff These operating instructions are aimed at the following target groups Users Users are persons that meet the following criteria They have been instructed in the use of the device T...

Page 8: ...ual serve to alert the user to these residual dangers 2 5 1 Hot surfaces The surfaces of the device can become very hot If touched they can cause skin burns u Do not touch hot surfaces or else wear su...

Page 9: ...ending on the application hazards due to heat and or corrosive chemicals may arise u Always wear appropriate personal protective equipment such as safety goggles protective clothing and gloves u Make...

Page 10: ...xes in yeast eggs etc For fat determination including acid hydrolysis such as the method according to Weibull Stoldt in food and animal feed the product is to be hydrolyzed to make the fat accessible...

Page 11: ...nfiguration 3 2 1 Front view 9 8 7 5 6 10 11 12 4 3 2 1 Fig 2 Front view 1 Sample aspiration tube 2 Lift device 3 Rinsing funnel 4 Rack 5 Hydrolysis vessel 6 Upper insulation plate 7 Lever 8 Power reg...

Page 12: ...in strument 3 4 Scope of delivery NOTE The scope of delivery depends of the configuration of the purchase order Accessories are delivered as per the purchase order order confirmation and deliv ery no...

Page 13: ...1200 W Number of hydrolysis posi tions 6 6 Approvals CE CSA CE CSA 3 5 2 Ambient conditions For indoor use only Max altitude above sea level 2000 m Ambient temperature 5 40 C Maximum relative humidit...

Page 14: ...glass components for damage u Damage that has occurred in transit should be reported to the carrier u Keep packaging for future transportation 4 2 Storage u Make sure that the ambient conditions are...

Page 15: ...p only when using a water jet pump NOTE Make sure that the power supply can be disconnected at any time in an emergency 5 3 Establishing electrical connections NOTE Observe the regulatory provisions w...

Page 16: ...sure that they match the specifica tions on the type plate u Make sure that all connected devices are grounded u Make sure that the power plug is freely accessible at all times u Insert the power cab...

Page 17: ...ies page 29 Waterjet pumpt see Chapter 10 1 2 Accessories page 29 Precondition R The suction tube is assembled See Chap ter 5 5 Assembling the suction tube page 16 u Moisten the vacuum tube with water...

Page 18: ...e is assembled See Chap ter 5 5 Assembling the suction tube page 16 u Moisten the rubber coupling with water u Slip over the rubber coupling on the suction tube u Make sure that the rubber coupling is...

Page 19: ...ip over the top rubber coupling on the sam ple aspiration tube u Make sure that the upper rubber coupling is in the correct position The sample aspiration tube is assembled u Assemble all upper rubber...

Page 20: ...ls of the hydrolysis vessel with 50 mL 4 M HCl NOTE Use quartz sand with a grain size of 0 3 0 9 mm 4 In case the grain size is too small it will clog the frit of the glass sample tube 4 In case the g...

Page 21: ...ondition R All installations are done See Chapter 5 Installation page 15 R The samples are prepared R The sample aspiration tube is assembled See Chapter 6 1 Assembling the sam ple aspiration tube pag...

Page 22: ...vessel is completely transferred u Repeat the rinsing step of the hydrolysis vessel three times u Remove the sample aspiration tube u Remove the glass sample tube from the rubber coupling u Perform a...

Page 23: ...the glass parts with commer cially available cleaning agents u If heavily soiled use ethanol or a mild detergent u WARNING Do not clean the glass sample tube with frit in an ultra sonic bath u Dry th...

Page 24: ...servicing B CHI Labortechnik AG 24 30 Operation Manual HydrolEx H 506 Component Action Frequency Control panel u Wipe down the display with a damp cloth Monthly Rubber couplings u Replace the rubber c...

Page 25: ...re connected properly u Make sure that the glass parts are not cracked or broken u Make sure that the hose is not por ous u Make sure that the water jet pump or vacuum pump is switched on u Close the...

Page 26: ...em Action Breakage hydrolysis vessel Precondition R WARNING Wear gloves during carrying out the following instruc tions u Let the temperature of the instrument decrease until it is the same as the amb...

Page 27: ...lations and statutory require ments regarding waste disposal u When disposing observe the disposal regulations of the materials used Materials used see Chapter 3 5 Technical data page 12 9 2 Taking ou...

Page 28: ...with the prior written permission of BUCHI 10 1 1 Spare parts Order no Image Insulation plate 11065169 Suction tube cpl 11064546 Set of hydrolysis vessels 2 pcs 11064547 Set of aspiration tubes 2 pcs...

Page 29: ...ass sample tubes PTFE 11067220 Holder for glass sample tubes stainless steel 11067219 Weighing support for hydrolysis vessels 11067040 Hydrolysis vessel carrier 11067492 Adapter clips for B 411 sample...

Page 30: ...n zh India BUCHI India Private Ltd IN Mumbai 400 055 T 91 22 667 75400 F 91 22 667 18986 india buchi com www buchi com in en Indonesia PT BUCHI Indonesia ID Tangerang 15321 T 62 21 537 62 16 F 62 21 5...

Reviews: