Technical sheets - Automation

MY HOME

5

- Temperature control probe mode with item HC4693, 

HS4693, L4693, N4693, NT4693 probe - FUN = 4 

Warning: 

physical configuration can only be used if a 99-zone temperature control 

central unit is installed in the system

This mode is different from the previous one in the fact that the external probe is not 
connected to Local Display. Being unable to autonomously establish the temperature, 
it must be associated to at least one probe, items HC4693, HS4693, L4693, N4693, or 
NT4693. The user is shown the temperature value measured by the associated probes, 
the set temperature value, and the adjustment of the local selector. 

ZA

Zone address

0 – 9, probe address

ZB

Zone address

1 – 9, probe address

MOD

Mode

1 – 8, Slave probe number

FUN

Function

4

For more complex systems, the probe can memorize the actuators to activate, and the
pumps to control on the BUS. The programming operation must be completed directly
from the central unit. The central unit can also be used for the calibration of the probe.
During the system setting stage, it will be necessary to specify the actuators used for
the heating system, and those used for the air conditioning system, as they operate in
a complementary way.

Functions

A short pressure of keys 8 and 11 can be used to locally change the temperature by  
+/-3°C, in relation to the settings received from the central unit. A short pressure of 
key 6 can be used to select the mode of operation, cycling through the OFF, antifreeze/
thermal protection, and automatic statuses respectively.

Each mode of operation is identified by a different icon. A short pressure of key 2 will
force the speed the fan-coils, cycling through speed 1, 2, 3 or automatic.

For simple systems, where each zone controls at most one heating actuator and one air
conditioning actuator, both of the ON/OFF type, and on a system with only one pump 
per function, the confi guration of the system can be performed by simply connecting 
the confi gurators that identify the address of the device and, in case of probe, indicate 
the number of slaves present.

The possible operations for the user are the adjustment of the set temperature using 
the local selector, and the change of status of the probe. In this mode, the parameters 
that can be configured are the local display address (which must coincide with the  
ZA/ZB address of the associated probe), the type of control of the pump, the type of 
mode, and the number of slave probes.

Example of configuration of a zone (address 47) with Local Display and probe
item HC4693, HS4693, L4693, N4693, NT4693

Local Display
(HC/HS/L/N/NT4891)

Sonda Slave
(HC/HS/L/N/NT4693)

Socket

Configurator

Socket

Configurator

ZA

4

ZA

4

ZB

7

ZB

7

MOD

1

MOD

SLA

FUN

4

SLA

1

Slave
probe

Local
display

 

HD4891 - HC4891 - HS4891

L4891 - N4891 - NT4891

BT00517-a-UK

Summary of Contents for HC 4891

Page 1: ...alled in the system to be configured using the software only Legend 1 OLED technologyTouch Screen 2 Configurator socket 3 BUS clamp 4 Clamp for the connection of the external temperature probe 5 USB c...

Page 2: ...Automation Temperature control Sound system etc functions 3 confirm the scenario by quickly pressing the display 4 tochangeorcreatenewscenariostobelinkedtotheotherkeys repeattheprocedure starting fro...

Page 3: ...tching ON FUN Function 2 Functions A quick pressure of keys 5 and 7 will respectively switch ON and OFF the associated amplifier If the associated amplifier is on an extended pressure of keys 5 and 7...

Page 4: ...icate the number of slaves present For more complex systems the probe can memorize the actuators to activate and the pumps to control on the BUS The programming operation must be completed directly fr...

Page 5: ...he temperature by 3 C in relation to the settings received from the central unit A short pressure of key 6 can be used to select the mode of operation cycling through the OFF antifreeze thermal protec...

Page 6: ...croll through the various linesusingicon4 Foreachmeasurementinterface bypressingbrieflyicon3itwillthen be possible to display the consumptions or the economic evaluation Press and hold down icon 3 to...

Page 7: ...r if icon 4 is disabled it will be possible to select icon 3 to pre force the load and avoid disconnection in case of intervention of the central unit when consumptions are exceeded If the loads are c...

Reviews: