Technical sheets - Automation

Main functions that can be set using the Tilocal Display software

Installation

Local Display is installed using a traditional procedure, using a box, support, and 
AXOLUTE or LIVINGLIGHT cover plate; the device is not fitted with a temperature probe. 
Therefore, it will not be necessary to comply with the probe installation requirements. 
The recommended installation height is 150 - 160 cm.

Main possible functions using the software:
-  selection of the operating mode to set for the device, temperature control, scenarios, 

sound system, load management, consumption display.

-   configuration of the settings of the probe and of its parameters;
-   definition of the type of temperature central unit;
-   parameters for the measurement of energy production, or consumption costs;
-   configuration of the general device parameters;
-   icon style definition.

Scenario programmer

In order to program, change or cancel a scenario, it is necessary to enable the 

programming mode of the Module item F420 so that the status LED is green (press the 

lock/unlock key on the Scenario Module for at least 0.5 seconds); continue with the 

following operations:
1)  press one of the four control keys the scenario should be associated to for 3 

seconds.  The screen shows the name and icon of the selected scenario and 

the programming bar, to indicate that the learning procedure has started  

If the device does not receive any input for 30 minutes from the start of the learning 

procedure, programming will automatically be interrupted;

2) set the scenario using the corresponding controls for the various Automation, 

Temperature control, Sound system, etc. functions;

3)  confirm the scenario by quickly pressing the display

4)  to change or create new scenarios to be linked to the other keys, repeat the procedure 

starting from point 1.

To call a set scenario just press its pushbutton on the control quickly.

1 2
3 4

scenario 2

scenario 4

scenario 1

scenario 3

A

Room

0 – 9, room of the scenario module 
item

PL

Light point

1 – 9, light point of the scenario 
module item F420

MOD

Mode

1 – 4, scenario number (*)

FUN

Function

1

- Scenario control mode - FUN = 1 

Thanks to this mode, it will be possible to manage and change 4 different associated 

scenarios of the F420 scenario module, and activate them by pressing one of the 4 icons 

shown on the display.

 

Local Display physical configuration

(*) Correspondence among the 4 icons and the numbers of the scenarios that can be 
saved in the F420 module

Configurator MOD

Icon 1

Icon 2

1

Scenario 1

Scenario 2

2

Scenario 5

Scenario 6

3

Scenario 9

Scenario 10

4

Scenario 13

Scenario 14

Configurator MOD

Icon 3

Icon 4

1

Scenario 3

Scenario 4

2

Scenario 7

Scenario 8

3

Scenario 11

Scenario 12

4

Scenario 15

Scenario 16

NOTE:

 Once the operations have been performed lock the programming, pressing the 

lock/unlock pushbutton, of the senario module, for at least 0.5 seconds, so that the 
corresponding LED becomes red.

To delete a scenario, proceed as follows:
1)  the scenario module must be enabled for programming.
2)  press the pushbutton of the scenario you want to cancel for at least 7 seconds; 

The display will confirm that the scenario has been deleted and return to the main 
screen. 
To erase the entire memory keep the DEL pushbutton on the Scenario module 
pressed for 10 seconds, the yellow “reset scenarios” LED flashes quickly. 

 

HD4891 - HC4891 - HS4891

L4891 - N4891 - NT4891

BT00517-a-UK

Summary of Contents for HC 4891

Page 1: ...alled in the system to be configured using the software only Legend 1 OLED technologyTouch Screen 2 Configurator socket 3 BUS clamp 4 Clamp for the connection of the external temperature probe 5 USB c...

Page 2: ...Automation Temperature control Sound system etc functions 3 confirm the scenario by quickly pressing the display 4 tochangeorcreatenewscenariostobelinkedtotheotherkeys repeattheprocedure starting fro...

Page 3: ...tching ON FUN Function 2 Functions A quick pressure of keys 5 and 7 will respectively switch ON and OFF the associated amplifier If the associated amplifier is on an extended pressure of keys 5 and 7...

Page 4: ...icate the number of slaves present For more complex systems the probe can memorize the actuators to activate and the pumps to control on the BUS The programming operation must be completed directly fr...

Page 5: ...he temperature by 3 C in relation to the settings received from the central unit A short pressure of key 6 can be used to select the mode of operation cycling through the OFF antifreeze thermal protec...

Page 6: ...croll through the various linesusingicon4 Foreachmeasurementinterface bypressingbrieflyicon3itwillthen be possible to display the consumptions or the economic evaluation Press and hold down icon 3 to...

Page 7: ...r if icon 4 is disabled it will be possible to select icon 3 to pre force the load and avoid disconnection in case of intervention of the central unit when consumptions are exceeded If the loads are c...

Reviews: