background image

Technical sheets - Automation

MY HOME

1

Configuration

Local Display may be configured in two ways:
-   physical configuration, by connecting the configurators to the appropriate sockets. 

This mode gives the possibility of configuring with basic parameters only 1 
function to manage, among the ones listed below. For the configuration of the 
advanced parameters use the TiLocalDisplay software.

-   from the PC, using the dedicated TiLocalDisplay software. This mode gives the 

possibility of configuring all the parameters, for the management of 1 to 4 
functions listed below.

Funzioni gestibili

-   Scenario control
-   Temperature control with external probe 3457
-  Temperature control with probe HD/HC/HS4693, L4693, N4693, NT4693.
-   Sound system
-   Consumption display
-  Load management
-   Advances scenarios (with MH200N programmer installed in the system), to be 

configured using the software only

Legend

1.   OLED technology Touch Screen
2.   Configurator socket
3.  BUS clamp
4.   Clamp for the connection of the external temperature probe
5.   USB connector

Front view

Description

Local Display is a device that gives the possibility of 4 home automation functions by 
means of simple and intuitive icons displayed on a 1.2” OLED display with touch screen 
technology. 
It can be used to manage the temperature control, sound system, energy management, 
and scenario functions.
The back of Local Display has a USB socket, which can be used to connect the device 
to a PC, to update the configuration, the set of characters, and the icon, as well as the 
firmware.

Technical data

-   Power supply from BUS:  

18 – 27 Vdc

-   Stand-by Absorption:  

max 10 mA @ 27 Vdc

   

 

 

max 15 mA @ 18 Vdc

-   Operating absorption:  

max 50 mA @ 27 Vdc

   

 

 

max 70 mA @ 18 Vdc

-   Operating temperature:  

5 – 35 °C

-   Size:     

 

2 flush mounted modules

1

Rear view

2

3

4

5

 

HD4891 - HC4891 - HS4891

L4891 - N4891 - NT4891

Local display

BT00517-a-UK

Summary of Contents for HC 4891

Page 1: ...alled in the system to be configured using the software only Legend 1 OLED technologyTouch Screen 2 Configurator socket 3 BUS clamp 4 Clamp for the connection of the external temperature probe 5 USB c...

Page 2: ...Automation Temperature control Sound system etc functions 3 confirm the scenario by quickly pressing the display 4 tochangeorcreatenewscenariostobelinkedtotheotherkeys repeattheprocedure starting fro...

Page 3: ...tching ON FUN Function 2 Functions A quick pressure of keys 5 and 7 will respectively switch ON and OFF the associated amplifier If the associated amplifier is on an extended pressure of keys 5 and 7...

Page 4: ...icate the number of slaves present For more complex systems the probe can memorize the actuators to activate and the pumps to control on the BUS The programming operation must be completed directly fr...

Page 5: ...he temperature by 3 C in relation to the settings received from the central unit A short pressure of key 6 can be used to select the mode of operation cycling through the OFF antifreeze thermal protec...

Page 6: ...croll through the various linesusingicon4 Foreachmeasurementinterface bypressingbrieflyicon3itwillthen be possible to display the consumptions or the economic evaluation Press and hold down icon 3 to...

Page 7: ...r if icon 4 is disabled it will be possible to select icon 3 to pre force the load and avoid disconnection in case of intervention of the central unit when consumptions are exceeded If the loads are c...