background image

11

31/07/2018

ST-00000361-

BUS

OFF

BUS 2   1

IP30

PRI

PRI 230 V~ 50 - 60 Hz  260 mA

346000

}

BUS

2 - 1

27V      1,2A

CEBEC

N

N F

BUS

PI

BUS

TK

PS

BUS

BUS

OFF

BUS

BUS

OFF

OFF

BUS

BUS

ON

ON

344642

344643

344612

344613

346000

344612

344613

346830

343081

343091

344642

344643

344612

344613

344612

344613

BUS

OFF

BUS 2   1

IP30

PRI

PRI 230 V~ 50 - 60 Hz  260 mA

346000

}

BUS

2 - 1

27V      1,2A

CEBEC

N

N F

BUS

PI

BUS

TK

PS

BUS

BUS

BUS

BUS

BUS

OFF

OFF

OFF

ON

344642

344643

344612

344613

346000

344612

344613

344612

344613

344612

344613

346830

343081

343091

344642 - 344643

EN

Wiring diagrams

DIAGRAM 5 - EXAMPLE OF TWO-FAMILY DIAGRAM

DIAGRAM 4 - EXAMPLE OF SINGLE-FAMILY DIAGRAM

VILLA 2

VILLA 1

Note:

• 

additional powersupply is not necessary;

 only one classe 300X13E in every apartment;

 only one classe 300X13E  in every local lan;

 max 3 internal units for apartment;

 classe 300X13E has to be installed only in installation tottally 2wire technology.

Note:

 additional powersupply is not necessary

• 

max 5 internal units for apartment

 classe 300X13E has to be installed only in installation tottally 2wire technology

CLASSE 300X13E

Touch Screen handsfree video internal units 

with Wi-Fi

Summary of Contents for CLASSE 300X13E

Page 1: ...n 400 mA Additional power supply of clamp 1 2 27Vdc Maximum absorption from clamp 1 2 250 mA Operating temperature 5 40 C The Classe 300X video internal unit must be connected to a Wi Fi network with...

Page 2: ...Installer Manual how to enable the functions The background and icons shown may differ from those on the device Front view Rear view Note When the DOOR ENTRY is connected to the system e g answer a c...

Page 3: ...s of the device identify the associated EP which is the first entrance panel that switches itself on when the pushbutton is pressed the first time as well as which door lock is activated when pressing...

Page 4: ...D 5 P 4 P 4 2 3 1 3 2 346210 1 1 23 4 1 23 4 P 3 MOD 9 P 3 1 23 4 EP door lock release configured with P 4 directly without call or activation of the actuator item 346200 346210 configured with P 4 an...

Page 5: ...2 N 1 N 3 N 3 N 1 N 2 P 1 MOD 5 P 1 P 1 2 3 1 3 2 346210 1 P 2 MOD 5 P 2 P 2 2 3 1 3 2 346210 1 MM 6 MM 7 MM 8 MM 9 N 2 N 3 N 4 N 5 N 1 N 1 N 4 N 3 N 5 N 2 N 1 N 4 N 2 N 5 N 3 N 1 N 3 N 2 N 5 N 4 N 1...

Page 6: ...hes and if closed the LED stays off WARNING the function can only be activated if required by the system accessory devices are required CANNOT BE ACTIVATED together with the PROFESSIONAL STUDIO OFFICE...

Page 7: ...he multi pair data cable CAT5 2 IU 2 pushbuttons 50 m 200 m 140 m 145 m 5 IU 5 pushbuttons 50 m 200 m 140 m 135 m 10 IU 10 pushbuttons 50 m 200 m 140 m 130 m 26 IU 26 pushbuttons 50 m 200 m 140 m 105...

Page 8: ...0 344642 344643 346020 344642 344643 346020 344642 344643 344642 344643 EN Wiring diagrams Below are some examples of connection of the CLASSE 300X13E 344642 344643 video handset in multi family 2 wir...

Page 9: ...344612 344613 344612 344613 344642 344643 344612 344613 344612 344613 346020 346020 31 07 2018 ST 00000361 344642 344643 EN Wiring diagrams DIAGRAM 2 EXAMPLE OF MULTI FAMILY SYSTEM WITH ADDITIONAL INT...

Page 10: ...346000 346850 F441 344642 344643 344612 344613 344612 344613 344612 344613 344612 344613 346000 346850 F441 344642 344643 344612 344613 344612 344613 344612 344613 344612 344613 346000 346850 F441 31...

Page 11: ...4612 344613 346000 344612 344613 344612 344613 344612 344613 346830 343081 343091 344642 344643 EN Wiring diagrams DIAGRAM 5 EXAMPLE OF TWO FAMILY DIAGRAM DIAGRAM 4 EXAMPLE OF SINGLE FAMILY DIAGRAM VI...

Reviews: